Tower server base unit for up to 8x 2.5 hot-plug drives, redundant non-hot-plug fans, 6x card extension slots, 2x bays for power supply units 1x optional hot-plug and lockable front bezel D3386 system board for up to 2x Xeon E5-v5 series processors, up to 12x DDR4 memory DIMM slots, 2x 1Gb onboard LAN, iRMC S5 server management incl. graphics controller and service LAN port ServerView Suite software incl. ServerView Installation Manager, Server View Remote Management and tools optional The system architect recommends 1x 450W power supply unit as default please confirm the required power for your configuration using the power calculator and select either 1x or 2x power supply units 2x for redundancy.Standard warranty3 years, On-Site Service, 5 days / 9 hours 5x9, local business hours, FTS wide / FTS.
Other Specifications Download Specification | |
---|---|
Processor Configuration | Intel Xeon Silver 4110 (2.10GHz/8-core/11MB/85W) |
Form Factor | Tower |
Processor Make | Intel |
Max. Number Of Sockets Available On Chipset | 2 |
Max. Number Of Sockets Populated With Processor | 2 |
No. Of Processor | 2 |
Number Of Core Per Processor | 8 |
Chipset Compatible With CPU | Intel® C624 |
Motherboard (OEMcompatible With CPU) | Yes |
PCI Slots (Express Gen 3.0 Min.) | 8 Expansion slots (in maximal optional configuration; 7x PCIe and 1xPCI-32) |
Max Nos Of PCI Lanes | 20 |
Memory ( DDR4 RAM Min.) | 16 GB |
DDR4 RAM Upgradable Upto (Minimum) | 768 GB |
DIMM Slots (Minumum) | 123 No. |
Hard Disk Drive Capacity | 3 x 600 GB GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 10000 RPM |
RAID Controller Caches | 1GB MB |
RAID Controller | PRAID CP400i |
RAID Controller Ports | 8-port 12Gb/s SAS3 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
Bays (min. 2 Internal Or More Hot Plug) | 8x 2.5-inch SAS/ SATA/PCIe |
USB Ports (version 2.0/3.0) | 8 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
DVD ROM (or Better) | 8x or better |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Not-Available |
FC HBA Dual Port Card Speed | NA |
Power Management | Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected |
Redundant Power Supply | Yes |
Redundant Fan | Yes |
Server Scalability To Be Achived Within The Box & Without Adding Nodes | Yes |
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | REGISTRATION/CRS 2015-1947/R-41023060 Date 10/07/2016 |
Name & Address Of Lab | BIS Delhi |
BIS Registration No. Under CRS Of Deity | GISTRATION/CRS 2015-1947/R-410230601 |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | PEC INT_RATE_BASE 2006=539 & SPECFP_RATE_2006=518 |
Declare Max. Power Consumption Of The System | 2 Nos. x Modular PSU 800W platinum hp |
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | SPEC INT_RATE_BASE 2006 & SPECFP_RATE_2006 |
Server Main Supply | 230V, ±10%,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 3 years |