Product DescriptionS.No.ParameterSingle PhaseUnitThree Phase Unit1Rating 15 KVA Servo Stabilizer2 KVA to 50 KVA6 KVA to 2000 KVA2Input Voltage Rangea 180V 280Vb 160V 280Vc 140V 280Va 350V 470Vb 340V 470Vc 320V 470Vd 300V 480Ve 270V 480Vf 240V 480V3Nominal Output Voltage230V400V4Output Voltage Accuracy 1 15LineFrequency Variation47Hz-53Hz .47Hz-53Hz6Effect of Power FactorNoneNone7Wave Form DistortionNone addedNone added8ControlDigital/AnalogueDigital/ Analogue9Response Time10 ms.10m s.10Voltage Correction Rate1. Air Cooled2 Oil Cooled25V / Sec.15V/ Sec40V / Sec25V / Sec.11LCD Display 20 x 2 matrixDate Time, Input Voltage, Output Voltage Current12Log book Memory Non-volatileNo. of Hrs. of operation on mainsPeak Current demandNos. of Abnormal High Voltage cut-off events.Nos. of Abnormal Low Voltage cut-off events.No. of Hrs. of operation on DG.13Programmable FeaturesThrough 2-parallel way r.
Other Specifications Download Specification | |
---|---|
Power Supply Type | AC |
Input For Power Supply | 300v to 470v |
Number Of Output Phase For AC Power Supply | Three Phase |
Number Of Outputs | 3 |
Waveshape Of Output | SINE |
AC Output Power | 22500 VA |
Programmable Output Frequency (Min.) | 45 Hz |
Programmable Output Frequency (Max.) | 55 Hz |
Programmable Output Frequency Resolution | NA Hz |
Output Voltage | Dual Value |
Output Current | Dual Value |
Output Voltage Range For AC Power Supply | 380V TO 420V V |
Setup Resolution For AC Power Supply (Voltage) | NA mV |
Accuracy For AC Power Supply (Voltage) | NA |
Readback Resolution For AC Power Supply (Voltage) | NA mV |
Readback Accuracy For AC Power Supply (Voltage) | NA |
Output Current Range For AC Power Supply | NA A |
Setup Resolution For AC Power Supply (Current) | NA mA |
Accuracy For AC Power Supply (Current) | NA |
Readback Resolution For AC Power Supply (Current) | V mA |
Readback Accuracy For AC Power Supply (Current) | NA |
DC Output Power | NA Watt |
Output Voltage Range For DC Power Supply | NA V |
Setup Resolution For DC Power Supply (Voltage) | NA mV |
Accuracy For DC Power Supply (Voltage) | NA |
Readback Resolution For DC Power Supply (Voltage) | NA mV |
Readback Accuracy For DC Power Supply (Voltage) | NA |
Output Current Range For DC Power Supply | NA A |
Setup Resolution For DC Power Supply (Current) | NA mA |
Accuracy For DC Power Supply (Current) | NA |
Readback Resolution For DC Power Supply (Current) | NA mA |
Readback Accuracy For DC Power Supply (Current) | NA |
Multiple Steps To Cover The Voltage And Current Ranges | Yes |
Line Regulation | NA % |
Load Regulation | NA % |
Total Harmonic Distortion (THD) | NA |
Output Ripple & Noise (Max.) | NA mVrms |
Transient Response | V µSec |
Protection | OV,LV,HV |
Display And Control Features | V,I |
Meter | DIGITAL |
Input-Output Interfaces | OPTIONAL |
Efficiency | 99 % |
Power Factor | 0.8 |
Certificates | Na |
Operating Temperature Range | 45 Degree C |
Operating Humidity Range | 45 % |
Accessories To Be Supplied | yes |
Availability Of Type Tests Reports From A Central Govt. Lab OR International Laboratory Accreditaion Cooperation (ILAC)or Their Worldwide Affiliated/ Recognised Labs OR NABL Approved Lab Showing Confirmity To The Specifications | Not-Available |
Name Of The Lab | na |
Address Of The Lab | NA |
Test Report No. And Date | NA |
Dimensions | 650X400X950 mmxmmxmm |
Weight | 80 Kg |
Warranty | 1 Year |