Mixed signal oscilloscope - smo1202a-s, 200mhz, 2 analog and 16 digital channels.
Other Specifications Download Specification | |
---|---|
Type | Mixed Signal |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | Yes |
No. Of Digital Channels | 16 Number |
Record Length Per Digital Channel Simultaneously | 14Mpts/CH GS/Sec GS/sec |
Sampling Rate Per Digital Channel Simultaneously | 500MSa/S Mega Points Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | Yes |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, Ground |
Time Base Range | 2ns–50 S/Div |
Trigger Types | Edge, Slope, Pulse, Video, Window, Interval, Dropout, Runt, Pattern, Serial Trigger |
Measurements | Voltage Measurements :Vmax, Vmin, Vpp,Vamp, Vtop, Vbase, Mean, Vmean, Stdev, Vstd, Vrms, Crms, FOV, FPRE, ROV, RPRE, Time : Period, Freq, +Wid , -Wid, Rise Time, Fall Time, Bwid, +Dut, -Dut, Delay, Time@Level, Delay : Phase, FRR, FRF, FFR, FFF, LRR, LRF, LFF, Statistics : Current, Mean, Min, Max, Std-Dev, Count, Math Functions : Add, Subtract, Multiply, Divide, FFT, D/Dt, Integration, Square Root. |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | Yes |
Acquisition Modes | Sample, Peak Detect, Averaging, High Res, Roll Mod |
Display Type | Colour |
Display Size | 20.32 CM |
I/O Interface | USB,LAN |
Standard Accessories To Be Supplied | 1:1/1:10 Probes, Power Cord, USB Cable, CD, Serial Deconde Key, MSO Function For SMO1000A-S, Logic Probe 16 Channel |
Operating Temperature Range | 10 To 40 Degree C Degree C |
Operating Humidity (RH) | 85% @ 65 C, 24 Hours % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | SMPL/105/17-18 |
Test Report Date | 25.11.17 |
Name Of The Lab | SMPL, Indore |
Warranty | 1 Year |
Real Time Bandwidth | 200 MHz |
Record Length Per Analog Channel Simultaneously | 14M points Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1GSa/S GS/sec |
Waveform Update Rate | 60,000 Wfm/S Waveforms/ |
Time Base Accuracy | 25 PPM |