The increasing impacts of pollutants and hazards to the health and industrial workers has resulted in effect on accurate, reliable and frequent assessment of work space pollution and worker-exposure. The data generation needed for corrective measures to safe the workers as per Factory act 1948 and amendment in 1986-87. Handy Sampler APM 831 used best light weight pump battery operated to suck air through 25mm dia filter and through suitable absorption solution contained in Impingers 2Nos fitted. Thus besides particulates any two gaseous pollutants can be monitored simultaneously. Rechargeable battery has been used with sufficient storage of power to operate the sampler for 8 hours. A charger is also provided with APM 831 to recharge the battery. The APM 831 system uses a small battery operated pump to draw air thorough a suitable absorption solution contained in an impinger. If necessary, 2 impingers can be used in series to monitor 2 gaseous pollutants..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Measurement Range | 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm |
Test Voltage | 50, 100, 250, 500 and 1000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 1 milliamper |
Operating Temperature Range | 0-95 Degree C |
Operating Humidity (RH) | 85 % |
Power Requirements | Battery Operated |
Type Of Battery | no |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | yes |
Dimensions (H X W X L) | 405x405x415 mm x mm x |
Weight | 50 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 21454 |
Test Report Date | 21-05-2017 |
Name Of The Lab | Star Labs |
Warranty | 1 |