Microtek High Frequency Online UPS provides Uninterrupted Pure Power for Critical Applications such as Computer Network, Servers, Cyber Cafes, ATM Machine, Labs etc. Rated Capacity 1 KVA / 900 WattsPhase Single Phase In, Single Phase Out Key FeaturesHigh Frequency and Double Conversion Online Technology.High End IGBT Based.High End Micro Controller Based.Wide Input Voltage RangeAdvanced PFC TechnologyAdvanced Battery ManagementAutomatic Battery Charging in UPS Off ModeShort Circuit and Overload ProtectionSmart RS232 Communication with monitoring softwareSNMP Card Slot OptionalOver Temperature Protection.EMI / RFI Noise FilterLCD/LED Display simultaneouslySpecially designed to suit Indian Power and Environment ConditionsGenerator Compatible Supplying Sinewave VoltageIsolation Transformer OptionalDifferent Output Voltage settings.Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.Static Bypass Enable or Disable.Outlets Programmable and Non Programmable.Protection from DC Fan failure.In-built Over Voltage Cut-Off Device. Technical Specifications ModelNM36MX1KK11-IBRated Capacity1 KVA / 900 WattsInput Input Voltage Range Load 50118 295 V 5 VInput Voltage range Load 50160 295 V 5 VFrequency40 70 Hz PhaseSingle Phase with GroundPower Factor 0.99 @ full load Output Voltage Range208 / 220 / 230 / 240 V ACFrequency Range Synchronized RangeFrequency Range Battery Mode47 53 Hz or 57 63 Hz50 Hz 0.1 Hz or 60Hz 0.1 HzTHD Linear Load 2THD Non Linear Load 4Overload 110, 30s turn to Bypass Mode 150 instant turn to BypassCrest Factor31 MaxShort Circuit Protection5 cycles turn Off Inverter, no transfer to Bypass,provide Alarm AC Mode, 5 cycles turn Off Inverter,provide AlarmBattery Mode, Input Fuse blown or Breaker actionWaveformPure SinewaveTransfer time AC Mode to Battery ModeInverter to Bypass ModeZero 4 ms Efficiency85 92 Battery DC Voltage36 V3 7.2 AH Battery insideCharge Current0.7 0.8 Amps Communication InterfaceRS232 SNMP OptionalIndicationLCD DisplayNoise LevelLess than 50dBA @ 1 Meter With Fan Speed ControlUPS Overload / UPS Short-Circuit110 / 300.
Other Specifications Download Specification | |
---|---|
Rating In KVA | 1 KVA |
Technology | MOSFET-PWM |
Input Power | single phase 160V - 260V sinewave,50Hz |
Output Power | single phase 230V ±1% sinewave,50Hz |
Backup Time | 30 Minutes |
Minimum VAH | 900 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | na % |
Overall Efficiency | 92 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | With |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | NA |
Type Test Certificate Date | NA |
Name Of Lab | NA |
Address Of Lab | NA |
Supply & Commissioning | SUPPLY |
Warranty | 2 Years |