× All the transactions performed on 2.0 is available here. To access Market click "Home".

10kva 3 phase igbt pure sine wave inverters (protonix igbt inverter)(10kva 3 phase igbt pure sine wave inverters)

` 160,000.00

  • MRP: `295000.00

PROTONIX IGBT INVERTERS employ cutting edge Digital Signal Processing Technology DSPT and IGBTS to provide most efficient power conversion besides attractive user friendly features.These Inverters broadly cover the following applications.i Off line inverter with contactor change overii Lift/ heavy duty motor invertersiii On line inverter with external chargeriv Solar inverters with MPPTv Air-conditioningvi Petrol pumpFeatures1. Single phase three phase2. No load shut down and load restart3. Single phase prevention4. Phase imbalance protection5. Phase sequence error protection6. Over load protection restart7. Short circuit protection restart8. Variable freq. drive Lift/Pumps etc9. Output voltage 220V 110. Load Regulation better than 511. Lo stage CCCV Better than 512. 4 stage mains charger 2A to 20 Amp13. Solar charger 10 Amp to 40 Amp14. Battery low cut restart15. Galvanic Isolation Transformer models16. 4 Line LCD Dis.

  • Availability: 99 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - Three phase 300 V - 450V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 320000 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 10 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power Three phase 300 V - 450V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 120 Minutes
Minimum VAH 320000 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 1 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. A1675/B
Type Test Certificate Date 26/11/2016
Name Of Lab RAb testing lab
Address Of Lab UJ 10, maghdut Tower indore Madhya Pradesh
Supply & Commissioning Yes
Warranty 3 Years

Price Dekho Price Dekho Price List in india