true rms digital insulaion multimeter (kusam meco)(KM 877)

` 26,030.00

  • Offered Price: ` 27400.00
  • MRP: `30500.00

3-5/6 Digit 6000 Counts Dual Digital LCD display with backlight.

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 5
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - No
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection Live circuit indicator 30 V to 600v ACDC,50 Hz
Pass Fail Function No
Data Logging NA
Software Not Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range 0 to 40 degree Degree C
Operating Humidity (RH) 90% %
Power Requirements Battery Operated
Type Of Battery 4 AA Alkaline batteries
PC Interface Available
Standard Accessories Supplied With The Equipment Test Probe Pair, BRP21S2-C Remote Probe, Alligator Clip Pair, Holster, User Manual and Carrying case
Dimensions (H X W X L) 208(L)x103(W)x64.5(H) mm x mm x
Weight 635 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 0511305
Test Report Date 05-11-2017
Name Of The Lab Kusam Meco
Warranty 1

Price Dekho Price Dekho Price List in india