MULTIFUNCTION POWER HARMONICS ANALYZER.
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Single phase |
Display Type | LCD Backlit |
Display Mode | digital |
Number Of Current Channels | 4 Nos. |
Number Of Voltage Channels | 4 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 1000vrms Volts |
Measurable Voltage Accuracy | .5% |
Measurable Voltage Resolution | .1vrms Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 1000A/3000A/5000A Ampere |
Measurable Current Accuracy | 2A |
Measurable Current Resolution | 1a Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 20Mw KW |
Power Accuracy | +/-10digits |
Power Resolution | .1Kw Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 60hz Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | .1% |
Resolution In Measurement Of Total Harmonics Distortion | .1% |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | n/a |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | .03 |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | n/a |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | n/a |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | n/a |
Measurable Crest Factor Accuracy | n/a |
Measurable Crest Factor Resolution | n/a |
Screen Memory | n/a |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 128 MB |
Type Of Battery Used | rechargeable NI-MH 7.2V 3.8MH |
Battery Backup | 7 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 1600 Grams |
Dimensions(LXWXH) | 262*173*66mm cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 40% degree celsius |
Operating Humidity | 90 % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Vol test leads, alligator clips, power adapter, power patch cord. |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | IP51 |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 1 |
TTC Report Date | 1/11/17 |
Name Of Lab | kusam meco |
Address Of Lab | mumbai |
Interface | usb, lan |