Fluke 15B digital multimeter.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.5 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 1.5 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 300 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 2.5 % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | NA % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0 to 40 Degree celcious |
Operating Humidity (RH) | ≤90 % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | 2 AA |
Total Voltage Of Battery | 1.5 Each |
Standard Accessories Supplied With The Equipment | Test leads with caps, 2 AA |
Dimensions (H X W X L) | 183 x 91 x 49.5 mm mm x mm mm x mm x |
Weight | 455 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 10100 |
Test Report Date | September 3, 2017 |
Name Of The Lab | ANAB |
Warranty | 1 Year |