Composite Fire Extinguisher Foam Based 2Liter meeting the general technical requirement as per EN 3 -7 A12007 Standard and test of conformity with EN 3-82006 as applicable. The special unique features of this Composite Fire Extinguisher are 1. 10 year guarantee against corrosion 2. 20 years shelf life life cycle 3. More than 40 reduced weight in comparison to metal body fire extinguisher. 4. Requires only a yearly inhouse compliance inspection by using the guage check with magnet by user. 5. Composite material gives a corrosion free product 6. Cylinder/Bottle Material HDPE with Aramid Winding Kevlar 7. Operating Head Material Brass - Nickle Plated 8. Nozzle Nylon Nozzle 9. 100 recyclable. 10. Each composite fire extinguisher is fitted with two pressure gauges for ease of self calibration with each other. 11. Neglible maintenance 12. No welding has been done on the extinguisher body. 13. The test report as per EN Standard. 14. Suitable for Class A, B, Electrical.
Other Specifications Download Specification | |
---|---|
Conformity To Standard | "EN 3-7 + A1: 2007 & EN 3-8;2006 with latest amdnt. " |
Marine Equipment Directive(MED) Approved | No |
Type | Stored Pressure |
Trolley | Without Trolley |
Extinguishing Media | Foam Based |
Foam Based Extinguishing Media | Aqueous Film Forming Foam (AFFF) |
Powder Based Extinguishing Media | NA |
Clean Agents Based Extinguishing Media | NA |
Halon Based Extinguishing Media ( As Per European Council Regulation 2037/2000 Concerning Use Of Halons) ( If Not Applicable Write NA) | NA |
Water Based Extinguishing Media ( If Not Applicable Write NA) | NA |
Wet Chemical Based Extinguishing Media ( If Not Applicable Write NA) | NA |
CO2 Based Extinguishing Media ( If Not Applicable Write NA) | NA |
Expellant Medium | N2 Based |
Class -A Fire Rating For (Powder Based, Water Based, Foam Based,Wet Chemical Based,CO2 Based,Halon Based Fire Extinguisher | 8A |
Class -B Fire Rating For (Powder Based, Foam Based CO2 Based Fire Extinguisher | 55B |
Nominal Permitted Charge For Powder Based Fire Extinguisher | NA kg |
Nominal Permitted Charge For Water Based, Foam Based, Wet Chemical Fire Extinguisher | 2 Ltrs |
Nominal Permitted Charge For C02 Based Fire Extinguisher | NA kg |
Nominal Permitted Charge For Halon Based Fire Extinguisher | NA kg |
Nominal Permitted Charge For Clean Agents Based Fire Extinguisher | NA kg |
Discharge Time | 18 second |
Discharge Range Of Fire Extinguisher | 3 meters |
Weight Of Filled Portable Fire Extinghuisher | 2.8 kg |
Operating Temperature, Max | 60 ° C |
Test Pressure(cylinder) | 22 Bar |
Height Of Cylinder | 410 mm |
Diameter Of Cylinder | 125 mm |
Rechargable | Yes |
Color Coding | Signal Red |
Fire Extinguisher Suitable For Class -C Fire | No |
Fire Extinguisher Suitable For Class -D Fire | No |
Fire Extinguisher Suitable For Class -K Fire | No |
Fire Extinguisher Suitable For Class -F Fire | No |
Availability Of Test Report From Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification | Yes |
Test Report No. | EN 11740 |
Test Report Date | 24-09-2016 |
Name Of The Lab | APARAGAZ |
Address Of The Lab | Vilvoordsesteenweg 156, BE - 1120 BRUZELLES/ Brussel |
Service Pressure | 12 Bar @ ° C |
Guarantee Against Corrosion | 10 Years |
Welding On The Extinguisher Body | No |
Cylinder/Bottle Material | HDPE with Aramid Winding (Kevlar) |