× All the transactions performed on 2.0 is available here. To access Market click "Home".

cctv power supply (erd 4pin)(erd lp116)

` 2,500.00

  • MRP: `3500.00

A/C Input Voltage - 230 Volts . DC Current Output Rating - 0 to 5 Ampere Maximum Power - 120 Watt .Load Regulation Voltage of output offset - less than 0.01 2 mV Line Regulation Voltage of output offset - less than 0.01 1 mV Over Voltage Protection Response Time - less than 10 mili sec . SUITABLE FOR 4 CCTV DOME/BULLET CAMERA..

  • Availability: 50 In Stock
  • Min. Qty. Per Consignee: 1
  • DC Current Output Rating - 0 to 4 Ampere
  • Maximum Power - 120 Watt
  • Load Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 2 mV
  • Line Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 1 mV
  • Over Voltage Protection Response Time - less than 10 milli sec
Other Specifications Download Specification
DC Voltage Output Rating 0 to 30 Volt
DC Current Output Rating 0 to 4 Ampere
Maximum Power 120 Watt
Load Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 2 mV
Load Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 1.5 mA
Line Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 1 mV
Line Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 0.1 mA
Over Voltage Protection Accuracy +- 0.5 + 0.5 V
Over Voltage Protection Response Time less than 10 milli sec
Ripple And Noise Voltage (20 Hz To 20 MHz) less than 1 mVrms less than 4 mVpp
Ripple And Noise Current (20 Hz To 20 MHz) less than 4 mArms
Readback Voltage Accuracy 0.05 + 10 mV
Readback Current Accuracy 0.15 + 4 mA
Readback Voltage Resolution 1 mV
Readback Current Resolution 0.1 mA
Operating Temperature 253 Degree C
Gperating Humidity (RH) 00 %
PC Interface USB
Dimensions 00 mm x mm x
Weight GPIB gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. na
Test Report Date na
Name Of The Lab na
Warranty 1 Year

Price Dekho Price Dekho Price List in india