× All the transactions performed on 2.0 is available here. To access Market click "Home".

10 KVA ONLINE UPS SINGAL PHASE AC INPUT AND SINGLE PHASE AC OUTPUT WITH 120 MINT BACKUP AND 33000VAH (micro power)(GAMA SERIES 10 KVA ONLINE UPS WITH 120 MINT BACKUP AND 33000 VAH)

` 165,013.20

  • Offered Price: ` 166680.00
  • MRP: `185200.00

On-Line UPS with isolation transformer suitable for single phase AC input single phase AC output, Floor Mounted Type Rating of UPS 10 KVA,Indicative Back-up time 120Minutes MICRO POWER UPS REGISTERED WITH NSIC DGSD.

  • Availability: 97 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 32500 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 10 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 120 Minutes
Minimum VAH 32500 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 1.8 %
Overall Efficiency 98 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. NTH(SR)/EL©/2014/00209B
Type Test Certificate Date 23.05.2014
Name Of Lab NTH
Address Of Lab CHENNAI
Supply & Commissioning On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type Rating of UPS: 1.0KVA,Indicative Back-up time: 30Minutes (MICRO POWER UPS REGISTERED WITH NSIC & DGS&D)
Warranty 2 Years

Price Dekho Price Dekho Price List in india