Keysight E3632A Programmable DC Power Supply 30V, 4A and 15V, 7A with offer essential features for a tight budget. The single output, 120W, GPIB, dual range outputs compact size for bench use low output ripple and noise as well as built-in measurements and basic programmable features with GPIB and RS232 interface. It is a high performance supply optimized for manual and basic automated testing and, with a combination of benchtop capabilities and system features, it is designed to help improve measurement quality and reduce test time. Standard 3 year warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent. Standard delivery period 60 days.
Other Specifications Download Specification | |
---|---|
DC Voltage Output Rating | 0 to 30 Volt |
DC Current Output Rating | 0 to 4 Ampere |
Maximum Power | 120 Watt |
Load Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 2 mV |
Load Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 1.5 mA |
Line Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 1 mV |
Line Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 0.1 mA |
Over Voltage Protection Accuracy | +- 0.5 + 0.5 V |
Over Voltage Protection Response Time | less than 10 milli sec |
Ripple And Noise Voltage (20 Hz To 20 MHz) | less than 1 mVrms less than 4 mVpp |
Ripple And Noise Current (20 Hz To 20 MHz) | less than 4 mArms |
Readback Voltage Accuracy | 0.05 + 10 mV |
Readback Current Accuracy | 0.15 + 4 mA |
Readback Voltage Resolution | 1 mV |
Readback Current Resolution | 0.1 mA |
Operating Temperature | 0 to 40 degree C Degree C Degree C Degree C |
Gperating Humidity (RH) | Up to 80% RH % % % |
PC Interface | USB |
Dimensions | 213 x mm W x 133 mm H x 348 mm D mm x mm x |
Weight | GPIB gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NTH(SR)/EL(C )/2013/048C |
Test Report Date | 18-02-2013 |
Name Of The Lab | NATIONAL TEST HOUSE (SR), Taramani Chennai |
Warranty | 3 Year |