× All the transactions performed on 2.0 is available here. To access Market click "Home".

fluke 376 true-rms acdc clamp meter with iflex (fluke)(fluke-376)

` 35,770.00

  • MRP: `40450.00

The Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.Additionally, the Fluke 376 includes the new iFlex flexible current probe, which expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter...

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 2
  • Display - Backlit
  • Measurement Type - True RMS
  • AC Current Measurement Range - 0 to 999.9 Ampere
  • AC Voltage Measurement Range - 0 to 1000 Volt
  • Inrush Current (Integration Time) - 100 millisecon
Other Specifications Download Specification
Type Hand Held
Display Backlit
Measurement Type True RMS
AC Current Measurement Range 0 to 999.9 Ampere
AC Current Measurement Accuracy + or - 2 %
AC Voltage Measurement Range 0 to 1000 Volt
AC Voltage Measurement Accuracy Upto 600 Volts + or - 1 %
AC Voltage Measurement Accuracy Beyond 600 Volts + or - 1.5 %
Inrush Current (Integration Time) 100 millisecon
DC Current Measurement Range 0 to 999.9 Ampere
DC Current Measurement Accuracy + or - 2 %
DC Voltage Measurement Range 1000 Volt
DC Voltage Measurement Accuracy + or - 1 %
Resistance Measurement Range 0 to 4000 Ohm
Resistance Measurement Accuracy + or - 1.5 %
Continuity < or = 30 Ohm
Frequency Measurement Range 10 to 400
Frequency Measurement Accuracy + or - 0.5
Jaw Size (Dia In Closed State) 34
Satety Rating Category III 600 V of IEC 61010 -2-D31
Operating Temperature Range 10°C – +50°C Degree C
Operating Humidity (RH) Non condensing %
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
Standard Accessories Supplied With The Equipment 18-inch iFlex™ flexible current probe,Coated instruction card,Safety information sheet,Soft carrying case,TL75 test leads,Two AA Alkaline batteries
Dimensions (H X W X L) 246 x 83 x 43 mm x mm x
Weight 388 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 21454
Test Report Date 21-05-2017
Name Of The Lab Star Labs
Warranty 1 Year

Price Dekho Price Dekho Price List in india