Microprocessor Controlled Blood Bank Centrifuge is a refigerated centrifuge design for blood component separation and is ideal to prepare packed cells,Platelet riched plasma,Platelet concentrate or cryop recipitate.Also useful for other specialized blood bank procedures such as Buffy coat seperation Preparation of leukocyte Poor red cells Platelets.The main unit is built on a study metal frame resting on leckable custers and enclosed by sheet metal removable panels finished in corrosion resistance paints.the centrifuge lid has as electrical interlock to ensure that the unit can not be run with cover open cover can not be opened unless motor comes to complete halt.Advanced Manufacturing Technique are used for resilient mounting of the heay duty brushless induction motor rsulting in low level of vibration and noise.The drive motor and hermetically sealed refrigerating compresses are located under the insulated rotocompartment.these are resiliently supported on study frame.The.
Other Specifications Download Specification | |
---|---|
Centrifuge Design | Bench Top |
Centrifuge Type | Mini centrifuge |
Speed Mode | Fixed Speed |
Rotor Configuration | Fixed Angle |
Interchangeable Rotors | YES |
Material Of Rotor | Aluminium |
Finish Of Rotor | Powder coated |
Autoclavable Rotor At 121 Degree Celsius | YES |
Type Of Drive Motor | Brushless DC Motor |
Controler Type | Microprocessor Controlled |
Body Material | Die cast Aluminium |
Finish Of Body | Powder coated |
Base Material | Die cast aluminium |
Lid Type | Transparent |
Lid Material | Steel |
Lid Lock Detector | YES |
Emergency Lid Lock Release | YES |
Automatic Braking | YES |
Number Of Sample Tubes Testable Simultaneously | 10 |
Volume Of The Tube Testable | 1.5/2 ml |
Maximum Speed | 10 RPM |
Minimum Speed | 10 RPM |
Speed Increment Step, If Variable Speed | 0 RPM |
Speed Control Accuracy Of Set Speed (+/-) | 10 RPM |
Maximum Relative Centrifugal Force(RCF) | 180 x g |
Calibration | Manual Calibration |
Temperature Control Method | Heating |
If Refrigerated, Refrigeration System Free From CFC/HCFC | YES |
Temperature Setting Range(increment Step) | NA Degree Celcius |
Temperature Control Accuracy Of Set Temperature(+/-) | 10 Degree Celcius |
Acceleration Time (full Speed) | 5 sec |
Deceleration Time( Full Stop) | 5 sec |
Number Of Acceleration/deceleration Profiles In-built | 10 |
Timer Provided | YES |
Timer Setting (Increment Step) | 1-25 min |
Input Method/Interface | Analog Front Panel |
Display Option/Output Read Out Option | Analog |
Type Of Data Logging Option | USB,PRINTER |
Rotor Imbalance Detection | YES |
Auto Cutoff | YES |
Pulse Mode | YES |
Programmable | YES |
Number Of Storable Programmes,If Programmable | 0 |
Input Voltage With Phase | 230 V |
Power Consumption | 250 W |
Input Current | 180 A |
Noise Level (maximum) | 55 db |
Ambient Operating Temperature | 18 Degree Celcius |
IP Rating Or Ingress Protection Rating | 68 |
External Dimension: Height | 75 mm |
External Dimension: Width | 50 mm |
External Dimension: Depth | 50 mm |
Weight Including Default Rotor | 155 kg |
Accessories And Spares Included In Standard Pack | ROTOR,TUBES,PCR STRIPS |
Additional Safety Features | AUYO CUTOFF |
Free Service Available | YES |
Warranty On Rotor And Machine | 1 Years |
Supply Of Free Spare Parts Under Warranty | YES |
Annual Maintenance Contract(AMC) Available After Warranty | YES |
AMC Contract Period | 1 Years |
Product Code Available On Supplier Website | YES |
If Yes, Product Code | 2388 |
Firm Certified To ISO9001:2008 Or Latest | YES |
Product Is CE Certified | YES |
If CE Certified, EN/IEC Directives | NA |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | NABL |
Test Report No. | 35887/16-17 |
Test Report Date | 24-10-16 |
Name Of The Lab | MPLUN |
Address Of The Lab | BHOPAL |
Number Of Free Services, If Provided | 2 |