greenmist fire extinguisher - 2 ltrs capacity (CEASEFIRE)(CF000035)

` 13,062.00

  • MRP: `14514.00

GreenMist System is designed to combat Class A, B, C, F and electrically started fires. Green Mist is an eco-friendly. LOW ATER USASE. This is completely water based and causes no collateral damage-NO HARM TO THE APPLICATION AREA- at all not to your premises nor the ozone. It tough on fire, yet gentle on the environment. through a specially designed nozzle, giving it a throw of over 10 feet. the patented Instalert System acts both as an instant fire alarm as wellas a theft deterrent..

  • Availability: 12 In Stock
  • Min. Qty. Per Consignee: 1
  • BIS Marking - Yes
  • CM/L No. with validity period - 8886112
  • Type - Stored Pressure
  • Extinguishing Media - Water Based
  • Clean Agents Based Extinguishing Media - NA
Other Specifications Download Specification
Conformity To Standard IS:15683:2006 With Latest Amdmnt.
BIS Marking Yes
CM/L No. With Validity Period 8886112
Type Stored Pressure
Trolley Without Trolley
Extinguishing Media Water Based
Foam Based Extinguishing Media NA
Powder Based Extinguishing Media NA
Clean Agents Based Extinguishing Media NA
Expellant Medium N2 Based
Fire Extinguisher Capacity( Foam Based/Water Based) 2 Ltrs
Powder Based Fire Extinguisher Capacity NA Kg
Carbon Dioxide Based Fire Extinguisher Capacity NA Kg
Clean Agents Fire Extinguisher Capacity NA Kg
Weight Of Filled Portable Fire Extinghuisher 4.86 Kg
Test Pressure For Foam Based/Powder(N≥20) / CO2 Based Fire Extinguisher(N≥35) 35 Bar
Burst Pressure,Min 55 Bar
Discharge Range For Class A Fire Extinguisher(≥2)/Class B (≥1) 2 Meters
Effective Discharge Time For Fire Extinguisher, Min 8 Seconds
Fire Rating For Class -A Fire Extinguisher NA
Fire Rating For Class -B Fire Extinguisher NA
Fire Extinguisher Suitable For Class -C Fire YES
Fire Extinguisher Suitable For Class -D Fire NO
Fire Extinguisher Suitable For Class -K Fire NO
Rechargebale YES
Color Coding Red
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification YES
Test Report No. 130626
Test Report Date HIMP/09/1746-2
Name Of The Lab Tested by CE & ERDA, WORKS ON Class A, B, C, F and electrically started fires, TESTS: HELIUN LEAK DETECTION, SHEET THIKNESS:1.60mm, F-RATING 15F, Valve Construction-Forging & Machining, Can Construction-Deep drawn & CO2 Mig welded, LOW ATER USASE. This is completely water based and causes no collateral damage-NO HARM TO THE APPLICATION AREA- at all not to your premises nor the ozone
Address Of The Lab CE & ERDA
Operating Temperature +5° C to + 55° C ° C
Fire Extinguisher Suitable For Class -E Fire YES