low pressure water mist and cafs back pack type fire extinguisher (mtpl)(mtpl 09-01)

` 150,000.00

  • MRP: `175000.00

The Water mist-cum CAFS Compressed air foam system fire fighting system shall work between 07 to 50 bar pressures with negligible recoil. The system shall be capable of carrying 9/10 L of water in the main vessel. Air cylinder, duly approved by PESO, Nagpur, shall have minimum rating of 4.7 liter 300 bars to be used for the discharge of fine water mist and CAFS through discharge gun. The same nozzle of the gun shall be suitable to fight Class A, Class B and also live electrical fire without any modification. Gross wt of the charged system along with air cylinder should not exceed 25 KG with plus 10 variation 25kg 10. The system should meet EN 3 standard requirement..

  • Availability: 50 In Stock
  • Min. Qty. Per Consignee: 1
  • Cylinder capacity - 4.7 Ltrs
  • Mounting type - Back pack
  • Configuration (Shall be mounted on a sturdy frame suitably cushioned for comfort, provided with shoulder pads for carrying as a backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.) - Yes
  • Fire Rating - 27 A, 233B, 1000V with Standard AFFF Compound conforming to UL-162
  • Spreading coefficient for Standard AFFF compound shall be +3 minimum - yes
Other Specifications Download Specification
Conformity To EN Standards EN 3-7:2004+A1:2007
Cylinder Capacity 4.7 Ltrs
Mounting Type Back pack
Configuration (Shall Be Mounted On A Sturdy Frame Suitably Cushioned For Comfort, Provided With Shoulder Pads For Carrying As A Backpack And A Handle To Be Carried By Hand. All Materials Used Shall Be Of Fire Retardant Type. Backpack Shall Be Supplied With Two Air Cylinders.) Yes
Pressure 8 Bar
Fire Rating 27 A, 233B, 1000V with Standard AFFF Compound conforming to UL-162
Type Of Foam Standard Foam as per UL 162 or IS 4989 Standards
If Special Foam Mention The Compostion For Special ,otherwise Put NA NA
Spreading Coefficient For Standard AFFF Compound Shall Be +3 Minimum yes
Spreading Coefficient For Special AFFF Compound Shall Be +5 Minimum Yes
Commercial Brand Name Of The Special Foam (fire Extinguishing Medium) As Per Accredited Laboratory Test Report Where In Fire Rating Has Been Achieved, To Be Declared. NA
The Concentration Of Compounds Shall Be Nominal 6% Yes
Extinguishing Medium Water Mist & CAF
Extinguishing Gun Material Stainless Steel
If Others Mentions The Material For Extinguishing Gun,otherwise Put NA SS316
Extinguishing Gun Weight 2000 grams
Lancing Distance Of Gun 13 meters
Length Of EN Marked Hose 1.3 meters
Pressure Vessel Material Stainless Steel
Pressure Vessel Capacity 9 Ltrs
Compressed Air Cylinder Capacity At 300 Bar 4.7 Ltrs
Pressure Gauge To Monitor Air Cylinder Pressure Yes
Compressed Air Cylinder Material Carbon composite
The Air Hoses Shall Be Suitable For Minus 40 Deg C To 100 Deg C Temperatures Yes
Flow Rate ( Must Be In Range Of 0.42 To 0.45) 0.45 ltr/sec
Operating Time In Full Throttle ( Must Be In Range Of 20 To 23) 20 seconds
Weight Of Fully Charged System (#) 26 kg
Main Components: Pressure Vessel To Hold The Media With Safety Valve, Compressed Air Cylinder Couped With A Reducer, Hose Pipes For Discharge Of Water Mist Media, Extingushing Gun yes
System Shall Be Designed For Maximum Operating Temperature TSmax And Minimum Operating Temperature TSmin Of 60 Deg C Or More And 5 Deg C Or Less Respectively And Certified By The Manufacturer Accordingly Yes
"The Air Cylinders Shall Have PESO, Nagpur Approval " Yes
Test Certificate No. 110031 & 212(1)FR/MTPL/2013/HIMP/09/109-2
Test Report Date 23/11/2011/28/01/2013/30/4/2012
Name Of Lab Where Test Conducted FTRL/CBRI/ERDA