× All the transactions performed on 2.0 is available here. To access Market click "Home".

mzdfmd with real time recording (samarth)(106-fy)

` 247,500.00

  • MRP: `275000.00

Micro controller Based. MZDFMD comes with unique feature of text on video technology. Conform to relevant electric safety standard Supported by Test Certificates from NABL India or other accredited labs from the country of origin of the equipment including SHOCK, BUMP,, DURABILITY,IMPACT RESISTANCE as per IEC -61010. All the Detector Parameters like Sensitivity, Threshold, Metal Level and IN-OUT count is being displayed at a time in the LCD and Monitor. Having inbuilt recording capacity..

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 10
  • Walk-through Arch (Outer Frame) Dimensions (H x W x D) - 2230x860x720 mmxmmxmm
  • Walk-through Arch (Inner Frame) Dimensions (H x W x D) - 2000x720x720 mmxmmxmm
  • Detection Area (H x W x D) - 2000x720x720 mmxmmxmm
  • Number of Detection Zones - 6
  • Door Frame is provided with base wheels for easy mobility - NO
Other Specifications Download Specification
Technology Transmitter and Receiver
Walk-through Arch (Outer Frame) Dimensions (H X W X D) 2230x860x720 mmxmmxmm
Walk-through Arch (Inner Frame) Dimensions (H X W X D) 2000x720x720 mmxmmxmm
Detection Area (H X W X D) 2000x720x720 mmxmmxmm
Detection Zones Multiple Zones
Number Of Detection Zones 6
Type Of Usage Indoor
"Construction Of Door Frame (Walk-through Arch)" Light weight, rigid, laminated side panels and cross piece with ABS plastic boots for panel protection
Door Frame Is Provided With Base Wheels For Easy Mobility NO
Door Frame Is Provided With A Floor Panel To Attach Both Side Panels To Give Stability & Rigidity To The Structure NO
Ramp Over The Floor Panel - Covered With Synthetic Carpet For Long Life NO
Door Frame Material ABS
Door Frame Is Water Proof NO
Door Frame Is Weather Proof YES
Operational Frequency Range LESS THAN 30 KHZ
Number Of User Selectable Frequencies 5
Adjustable Sensitivity YES
Number Of Sensitivity Levels / Steps 0-255
Metals Which Can Be Detected Ferrous, Non-Ferrous, Ferrite & Alloys
Capability Of Metal Detection In Entire Frame Area Uniformly in entire Frame Area
Capability Of Metal Detection In All Orientations YES
Capability Of Metal Detection In Walking Speed Of Interception YES
Audio-Visual Indication On Detection At Side Panels And Control Panel YES
Audible Alarm On Detection With Adjustable Volume YES
Back-lit Display LCD
Display Of Zone Intercepted YES
False Alarm Rate %
Traffic Counter (inbound / Outbound) For Counting Number Of Persons Passing The Sensing Zone YES
Walk / Stop Indicator For Traffic Control YES
DFMD Should Not Interfere With Adjacent Installed DFMDs Within A Distance Of 1 Foot YES
DFMD Should Not Be Affected By Opening / Closing Of A Metallic Gate In Vicinity YES
DFMD Should Not Be Affected By Heavily Reinforced Floors / Roof Tops / Walls YES
DFMD Should Not Be Affected By External RF Transmission And EMI (Electro Magnetic Interference) YES
Capacity / Throughput Rate 50 person/min
In-built Auto Calibration Capability YES
User Friendly Self-testing Diagnostics To Identify Faulty Condition YES
Control Panel Easy accessible control panel, with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and / or by password.
Power Supply 220 V AC, 50 Hz, Mains + 10
Battery Standard UPS
"Details Of Battery / UPS (Type / Make / Capacity -VAH, Etc)" OPTIONAL
Battery Back-up In Full Function 2 hrs hours
Audio-Visual Low Battery Indicator YES
DFMD Should Be 'Data Safe' YES
DFMD Shall Be Harmless To Wearers Of Pacemakers, Defibrillators Or Other Vital Support Systems, Pregnant Women And Magnetic Storage Media (floppy Disks, Audio Cassettes, Video Cassettes And Similar) YES
DFMD Should Conform To International Security Standards Of Safety / Radiation YES
Warranty 3 Years
One Test Sample For Each Machine For Tesgting During Commissioning / Maintenance Inclusive in the scope of supply
Training Tools- Charts, Slides, Training Brochure, Training Work Model, Blowup Diagram, Video Films On Demonstration And Use Etc. Inclusive in the scope of supply
Technical Manual Giving Full Description Of The Item, User's Handbook And Literature On Preservation / Maintenance, Procedure For Packing, Handling, Transportation, Storage And Battery Replacement Inclusive in the scope of supply
Practical Training At least one day in each quarter of the year continuing during warranty period
Operating Temperature Range & Relative Humidity -10 to + 70 deg C with humidity 95% non condensing
Availability Of Spares For A Period Of 7 Years After The Warranty Period YES
Availability Of Test Reports From Central Govt / NABL / ILAC Accredited Lab Covering All The Parameters As Per Specifications YES
Test Report No. EMI113
Name Of Test Lab ERTL
Address Of Test Lab ANDHERI MUMBAI
Hyper Link To Test Report NOT AVAILABLE

Price Dekho Price Dekho Price List in india