Technical Details Weight 230 g incl. battery Dimensions 100 x 75 x 45 mm H x W x D Housing material over molded 2 K Ingress protection IP67 Frequency 2.6 3.0 kHz Function indicator bi-color LED Alarm 95 dB at 3 m 2 ultra bright LEDs Pre-alarm 2 signals/second at reduced noise level Full-alarm 3 signals/second at maximum noise level Battery 2 AA LR6 cells Battery life 200 hours stand-by 10 hours alarm time Warranty 2 years excluding battery motionSCOUTNext Generation Stand-alone Personal Alert Safety System The next generation of stand-alone personal alert safety systems motionSCOUT detects the cessation of bodily movement and activates an automatic alarm. For enhanced safety the alarm can be activated manually also.motionSCOUT is extremely simple to use. The sensitive, electronic motion sensor recog-nises all normal body movements. Maintenance-free and durable motionSCOUT guarantees a great cost-performance-ratio. Stand-Alone Personal Alarm Safety System - Bid SpecificationRed marked words are related to one of the 8 existing motionSCOUT versions for internal use onlyFor creating a specific bidding document just for ONE motionSCOUT version, please delete the options not required, e.g. the grey marked text.Physical CharacteristicsSize- Instrument shall have the following approx. size 95 mm x 70 mm x 44 mmWeight- Instrument shall weigh no more than 225 g including clip and batteriesVersions- Instrument shall be available in two versions, activated either by On/Off button or by pulling out the key.Materials- All hardware, brackets, or fasteners of the instrument or any accessory shall be free of rough spots, burrs, or sharp edges.Handling- Instrument shall be easy to operate.Upper housing- Should consist of two components, silicone overmoulded, with integrated bumpers.Housing- Housing components shall not need separate gaskets.Belt clip- The harness / belt attachment shall offer a width of more than 55mm.Operational CharacteristicsTurn-On- Depending on the version the instrument shall be turned on by pushing the On/Off button or by pulling out the key.Confidence Signals - The instrument shall emit a welcome sound and indicating by a green flashing status- LED that the instrument is working correctly with enough battery capacity.Alarm button- Instrument shall have an alarm button with a diameter bigger than 20mm to offer easy operability even wearing protective gloves.Inadvertent Shut-off - The instrument must be designed to be protected against accidental shut-off.Shut-off- The instrument shall be switched off by pressing the On/Off button and the AlarmStandard Version - button for min. 4 seconds at the same time.Shut-off - The instrument shall be switched off by pushing the key into the bottom side of theKey Version housing and push the ON / OFF button for min. 4 seconds.User InterfacesLEDs- The instrument shall have three LEDs. One stating the battery status and the instrument is operational. Two red LEDs to visualize alarms.Instrument AlarmsVisual Alarms- Instrument must contain of two bright red flashing LEDs for motion and manually activated alarm visible from the front, top and sides. Thus it shall contain a standard, status-LED for battery alarm. All three LEDs shall be able to state the malfunction of the instrument. Audible Alarm- The audible alarm is divided in pre-alarm and full alarm. The pre-alarm shall run through three different sound pattern to get into the full alarm. The full alarm shall be rated at no less than 95 dB @ 3m. Before the battery alarm will be shown visually there shall be a short acoustic warning.Motion Alarm- Instrument must be equipped with visual and audible alarms. Audible alarms sound at an average of 95 dB @ 3m. Visual alarms shall be bright and must be viewable from top, front and sides.Battery Alarm- Red flashing status-LED together with a prior short acoustic warning with a remaining battery capacity of 1 hour full alarm.Thermal Alarm Version with Temperature Sensor- The instrument should feature a thermal warning. If the internal temperature exceeds the limit of the instrument a two-tone sound Hi-Lo every 2 1/2 second shall be emitted while this condition persists.Alarm Reset FunctionVersion with Manual Alarm Reset- The instrument should offer the possibility to reset the alarm manually. The manual alarm reset function should offer an additional tactical function where needed. Instruments Power-Battery- Instrument shall be powered by replaceable two AA cells.Service time -Fresh batteries shall offer more than 200 hours of motion sensing or more than 8 hours in full alarm.Battery Life Indication - A bi-colour status-LED shall provide the information Enough battery capacity shall be shown with a green flashing. Low battery capacity shall be indicated by a short acoustic warning followed by a red flashing. Test - Water / Dust Ingress- The Instrument shall resist the ingress of dust and water with rating of IP67 in accordance with International Standard EN 60529 Degrees of Protection Provided by Enclosures IP Code.Impact / Drop Test- The instrument must survive eight subsequent drops from 2 meter onto concrete surface so that the impact is on each face, one corner and one edge.Vibration- The instrument shall be resistant to vibration and must be conform to MIL-STD-810 E, Category 3, loose cargo transport.Flame engulfment test - The instrument shall be tested according EN1372006 chapter 7.4.1.3.RFI / EMC-The instrument shall not interfere with standard fire-fighter radio frequency bands at power levels found in hand-held 3 - 5W and vehicle mounted systems 100W. Communication / electronic devices cannot affect the instrument. The functionality is not compromised when the instrument is subjected to RF interference of 80 MHz to 1 GHz at 30 V/m. The instrument must meet RFI emissions and susceptibility of CE, according to EN 61000-6-2 und EN 61000-6-3.Operating - -20C to 55CTemperatureThermal Tolerance - The instrument is designed to have the following temperature tolerances when taken from room temperature into the following ambient temperaturesAmbient Temperature - The instrument should have the following full alarm time80C 176F - 600 minutes120C 248F - 30 minutes250C 482F - 8 minutes-30 C -22F - 120 minutes-40C -40F - 60 minutesAmbient- Version with Temperature SensorTemperature - The temperature alarm should be activated after90C 194F 90 minutes120C 248F 25 minutes150C 302F 17 minutes180C 356F 12 minutes 250C 482F 5 minutesCertificationsIntrinsic Safety Approval - The instrument must meet the approval ATEX II 1G Ex ia IIC T3/T4 -20C Ta 55CMaintenance Warranty Maintenance- Instrument shall be maintenance-free over its lifetime.Warranty- The instrument shall have a full two-year warranty.Instruction Manual A printed multilingual manual must be included as standard equipment..
Other Specifications Download Specification | |
---|---|
Device Is Capable To Operate In Hazardous Condition And To Remain Intrinsically Safe | Yes |
Device Is Capable To Raise Continuous Audio Vvisual Distress Alarm Automatically When The Unit Experiences No Movement Including Vibration For More Than 25 Seconds | Yes |
Modes Of Operation Available In The Device To Be Actuated By Rescue Personnel | off, manual, and automatic |
Availability Of Accidental Deactivation | Two stage manual actions to switch the unit from automatic mode to off position |
Availability Of Distress Tone Signals | Operational Signal, Pre Alert Signal & Alert Signal |
Audio Distress Signal Output At 3 Meter Distance | 90 dBA |
Distress Alarm Count At Full Noise Level | 2 audio signals per second |
LED Indicator To Show The Unit Is 'ON' | Green |
LED Indicator To Indicate When Distress Alarm Is Raised | Red |
Upper Frequency | 3000 (+/- 200) Hz |
Pre Alarm Level For 6 Seconds | 75 - 85 dBA |
Battery | Compatible with DSU |
Standby Battery Life After Full Charge | 100 Hour |
Alarm Duration When Loaded With Fully Charged Battery Of Designated Capacity | 6 - 8 Hour |
Alarm Duration After Battery Low Signal Alarm | Minimum 2 Hour |
Integrated Temperature Sensor | when the fire-fighter exceeds a predetermined time- weighted average temperature threshold, the audible heat alarm is activated |
Device Should Have Sensor Temperature Control Facility During Operation | Yes |
Motion Sensor | 3-axis accelerometer capable to Sense a broad range of motion |
Inbuilt Intelligence To Remove Chance Of False Alarm | Available |
Motion Sensor Timings Should Be Configurable According To Preference By Means Of Suitable Module Through PC. | Yes |
Unit Shall Be Compatible With All SCBA. It Can Be Worn With Or Without Breathing Apparatus. | Yes |
Dimensions Suitable To Be Worn With Self Contained Breathing Apparatus (SCBA) | Dimensions 100 x 75 x 45 mm [H x W x D] |
Weight (With Batteries) | 20 Gram |
Display | Alphanumeric, L.E.D. read-out of PASS status |
Compliance To IP 67 Requirements | Yes |
Operating Temperature Range | 20 - 65 Degree C |
Case : Rugged, High Temperature & Impact-resistant, Translucent, Encapsulated In A Durable Glowing Silicone Sleeve | Available |
Automatic Full "self Check" Function Upon Start Up | Available |
Accidental Switch Off During Use | eliminated by the options of tally insertion or two-button push, depending on the operating mode |
DSU Should Be Free Of Periodic Maintenance Except Pre Planned Battery Replacement As And When Required. | Yes |
National/International Certification Of The Device For Use By The Emergency Service Personnel | Available |
Name Of The Certification | Certifications Intrinsic Safety Approval - The instrument must meet the approval: ATEX II 1G Ex ia IIC T3/T4 [-20°C ≤ Ta ≤ +55°C] |
Certification No. And Date | Tests EMC [2004/108/EC]: EN 61000-6-2, EN 61000-6-3 MIL-STD-810E Flame engulfment acc. EN 137 EN 60529 [IP 67] JCDD/38 [for UK] Corrosion: EN 60068-2-11 |
Validity Of Certificate, If Any | Y |
Warranty | 1 Year |