Central Oxygen Generator Plant For Bed Capacity 101 To 150 Bed. Oxygen Generators Have Revolutionised The Concept Of Modern Hospitals By Bringing In Quality, Safety And Economy To Hospitals Making Them Self-Sufficient With Their Oxygen Needs..
Other Specifications Download Specification | |
---|---|
Conformity To ISO 80601-2-69:2014 Of The Medical Electrical Equipment – Part 2-69: Particular Requirements For Basic Safety And Essential Performance Of Oxygen Concentrator Equipment | Yes |
Flow Rate (Minimum) At 93% + - 3% Oxygen Purity | 86 Litres per minute |
Type | Fixed |
Battery Duration (If Battery Operated Or Electrical Cum Battery Operated) | 0 Hrs |
Battery Charging (If Battery Operated Or Electrical Cum Battery Operated) | 0 Hrs |
Oxygen Outlet(s) | Single |
Outlet Pressure | 441.29 KPa |
Power Consumption | 7500 Watt |
Operating Temperature Range | 50 degree C |
Operating Humidity Range | 80 % |
Operating Altitude Range | 1524 Meters |
Type Of Operation | Continuous Flow Type |
Adjustable Air Delivery Mechanism | Yes |
Oxygen Concentration Monitor | Yes |
Oxygen Tank Capacity | 1000 Ltrs |
Noise Level | 68 dB |
Continuous Flow | 86 LPM |
Digital Display | LCD |
Audio Alarm | YES |
Visual Alarm | YES |
Alert Of Technical Fault | YES |
Alert Of Wrong Battery | YES |
Alert Of Depleted Battery | YES |
Alert Of High Breath Rate | YES |
Alert Of Low Oxygen Purity | YES |
Alert Of No Breath | YES |
Alert For No Flow | YES |
Alert For Low Flow | YES |
Alert For High Flow | YES |
Alert Of Low Pressure | YES |
Alert Of High Pressure | YES |
Alert Of High Temperature | YES |
Alert For Power Failure | YES |
Alert For Service Requirement | YES |
Weight | 1250 Kg |
Dimensions (Length) | 3048 mm |
Dimensions (Width) | 3048 mm |
Dimension (height) | 1828.8 mm |
Flame Retardant | YES |
Manufacturer Warranty Period | 1 Years |
Spare Part Availability | YES |
Comply With International Standards | YES |
Name Of International Standards | AirSep |
FDA Approved | YES |
Availability Of Test Report CE Or EC Certification In Accordance With Appendix II(excluding Section 4) Of Medical Device Directive 93/42/EC & Its Amendment Or Equivalent | CE |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | NABL |
Test Report No. | TH/A/02/13/353 |
Test Report Date | 23/02/2013 |
Name Of The Lab | Envirocare Labs Pvt.Ltd. |
Address Of The Lab | Enviro House, A7, MIDC, Wagle Industrial Estate, Main Road, Thane |
Power Source | Electrical Operated |
Power Efficiency | 87 W/LPM |