Single Phase Power Quality Analyzer with 40MHz bandwidth Oscilloscope, Two 5,000-count true-rms digital Multimeters, Connect-and-View trigger simplicity for hands-off operation, Power measurements W, VA, VAR, PF, DPF, Hz, Resistance, continuity, diode and capacitance meter measurements, Voltage, current and power harmonics, Save or recall data and instrument setups, External optically isolated USB interface to transfer, archive and analyze scope or meter data, Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz, Fluke View ScopeMeter Software for Windows, Rugged design to withstand 3g Vibration, 30g shock, and rated IP51 according to EN/IEC60529,Highest safety rating in the industry safety rated for CAT IV 600 V,Li-Ion rechargeable battery, Warranty-03 Years.
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Single phase |
Display Type | LCD Backlit |
Display Mode | A, -A, B, -B |
Number Of Current Channels | 01 Nos. |
Number Of Voltage Channels | 01 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 750V Volts |
Measurable Voltage Accuracy | ±1% |
Measurable Voltage Resolution | 0.01 Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 400A Ampere |
Measurable Current Accuracy | 1.5% |
Measurable Current Resolution | 0.5mA Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 1560000 KW |
Power Accuracy | ±2% |
Power Resolution | 0.01W Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 40 MHz Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | ± 2.5 % |
Resolution In Measurement Of Total Harmonics Distortion | 0.01 |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 51 |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | 0.04 |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | ± 0.04 % |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | NA |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1-10 |
Measurable Crest Factor Accuracy | NA |
Measurable Crest Factor Resolution | 0.01 |
Screen Memory | Internal memory can store 20 data sets, Rest can be stored in External Memory Card |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 400 M samples Recorded Time MB |
Type Of Battery Used | Lithium Ion |
Battery Backup | 07 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 1.4 kg (3.2 lb) including battery pack Grams |
Dimensions(LXWXH) | 25.9 X 13.2 X 5.5 cm cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 0 to 50 °C degree celsius |
Operating Humidity | 10-30 degree-95%, 30-40 degree-75%, 40-50 degree-45% % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Fluke 125B Hand-Held Oscilloscope, Shielded Test Leads with Black Ground Leads , Test Lead Black (for Grounding) , Hook Clips (red, blue) , Banana-to-BNC Adapters (black, x1) , 10:1 Voltage Probe , i400s AC Current Clamp , USB Angled Adapter ,Switch Mode Power Supply, Adapter/Battery Charger , Rechargeable Li-ion Battery Pack , Soft Carrying Case , Magnetic Hanger , FlukeView® ScopeMeter® Software for Windows® , Screen Protector |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | IEC 61010-2-033: CAT IV 600 V/CAT III 750 V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 201754 |
TTC Report Date | 01.12.2017 |
Name Of Lab | FLUKE CORPORATION |
Address Of Lab | USA |
Interface | Optical to USB, |