THIRTY THREE ZONE WITH 20 INDEPENDENT PROGRAMS TO MEET ECAC REQUIREMENT OF EUROPEAN AIRPORTS AND TSA OF USA AIRPORT. 2300 SELECTABLE OPERATING FREQUENCY AND MULTIPLE CHANNELS.ADVANCED ANALOGUE AND DIGITAL FILTERING - WITH ADJUSTABLE OPERATING FREQUENCY TO ELIMINATE POTENTIAL EFFECT ON X-RAY UNITS, RADIO AND ELECTRICAL INTERFACES SOURCES. COUNTING FACILITY.RANDOM ALARM FEATURE ON A SELECTED PERCENTAGE OF NON ALARMING PERSONS. AUDIBLE TONE AND VOLUME ADJUSTABLE. BRIGHT LEDS ON BOTH PANELS.MEETS ELECTRICAL SAFETY AND COMPATIBILITY REQUIREMENT FOR CE , FCC, CSA, IEC CB CERTIFICATION, ICNIRP AND IEEE. SOLAR PANEL OPTIONAL. DIGITAL SIGNAL PROCESSOR PROVIDE GREATER SENSITIVITY, NICE IMMUNITY, DISCRIMINATION, DETECTION UNIFORMITY.INTERNAL BATTERY. FLOOR MOUNTING OPTION.EXCLUSIVE MULTIPLE TARGET PIN POINTING WITH 33 DISTINCT ZONES SHOWS PRECISE TARGET LOCATION ON THE LEFT, CENTRE AND RIGHT SIDE OF THE BODY FROM HEAD TO TOE..
Other Specifications Download Specification | |
---|---|
Technology | MICROPROCESSOR BASED PULSE INDUCTION TECHNOLOGY |
Walk-through Arch (Outer Frame) Dimensions (H X W X D) | 2200mm x 900mm x 580mm mmxmmxmm |
Walk-through Arch (Inner Frame) Dimensions (H X W X D) | 2000mmx 760mmx580mm mmxmmxmm |
Detection Area (H X W X D) | 2000mmx 760mmx580mm mmxmmxmm |
Detection Zones | Multiple Zones |
Number Of Detection Zones | 33 |
Type Of Usage | Outdoor |
"Construction Of Door Frame (Walk-through Arch)" | Light weight, rigid, laminated side panels and cross piece with ABS plastic boots for panel protection |
Door Frame Is Provided With Base Wheels For Easy Mobility | YES |
Door Frame Is Provided With A Floor Panel To Attach Both Side Panels To Give Stability & Rigidity To The Structure | YES |
Ramp Over The Floor Panel - Covered With Synthetic Carpet For Long Life | YES |
Door Frame Material | scartch and mark resistant laminate.detection head and support : heavy duty aluminium with heavy duty boot panel. |
Door Frame Is Water Proof | YES |
Door Frame Is Weather Proof | YES |
Operational Frequency Range | 1-2300 |
Number Of User Selectable Frequencies | 2300 |
Adjustable Sensitivity | YES |
Number Of Sensitivity Levels / Steps | 200 |
Metals Which Can Be Detected | Ferrous, Non-Ferrous, Ferrite & Alloys |
Capability Of Metal Detection In Entire Frame Area | Uniformly in entire Frame Area |
Capability Of Metal Detection In All Orientations | YES |
Capability Of Metal Detection In Walking Speed Of Interception | YES |
Audio-Visual Indication On Detection At Side Panels And Control Panel | YES |
Audible Alarm On Detection With Adjustable Volume | YES |
Back-lit Display | LCD |
Display Of Zone Intercepted | YES |
False Alarm Rate | 3 % |
Traffic Counter (inbound / Outbound) For Counting Number Of Persons Passing The Sensing Zone | YES |
Walk / Stop Indicator For Traffic Control | YES |
DFMD Should Not Interfere With Adjacent Installed DFMDs Within A Distance Of 1 Foot | YES |
DFMD Should Not Be Affected By Opening / Closing Of A Metallic Gate In Vicinity | YES |
DFMD Should Not Be Affected By Heavily Reinforced Floors / Roof Tops / Walls | YES |
DFMD Should Not Be Affected By External RF Transmission And EMI (Electro Magnetic Interference) | YES |
Capacity / Throughput Rate | 50 persons per minute person/min |
In-built Auto Calibration Capability | YES |
User Friendly Self-testing Diagnostics To Identify Faulty Condition | YES |
Control Panel | Easy accessible control panel, with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and / or by password. |
Power Supply | 220 V AC, 50 Hz, Mains + 10 |
Battery | Re-chargeable, maintenance free, in-built battery with charger |
"Details Of Battery / UPS (Type / Make / Capacity -VAH, Etc)" | 12V,14Ah |
Battery Back-up In Full Function | 10Hrs. hours |
Audio-Visual Low Battery Indicator | YES |
DFMD Should Be 'Data Safe' | YES |
DFMD Shall Be Harmless To Wearers Of Pacemakers, Defibrillators Or Other Vital Support Systems, Pregnant Women And Magnetic Storage Media (floppy Disks, Audio Cassettes, Video Cassettes And Similar) | YES |
DFMD Should Conform To International Security Standards Of Safety / Radiation | YES |
Warranty | 3 Years |
One Test Sample For Each Machine For Tesgting During Commissioning / Maintenance | Inclusive in the scope of supply |
Training Tools- Charts, Slides, Training Brochure, Training Work Model, Blowup Diagram, Video Films On Demonstration And Use Etc. | Inclusive in the scope of supply |
Technical Manual Giving Full Description Of The Item, User's Handbook And Literature On Preservation / Maintenance, Procedure For Packing, Handling, Transportation, Storage And Battery Replacement | Inclusive in the scope of supply |
Practical Training | At least one day in each quarter of the year continuing during warranty period |
Operating Temperature Range & Relative Humidity | -20 Degree C to +70 Degree C |
Availability Of Spares For A Period Of 7 Years After The Warranty Period | YES |
Availability Of Test Reports From Central Govt / NABL / ILAC Accredited Lab Covering All The Parameters As Per Specifications | YES |
Test Report No. | 235278 |
Name Of Test Lab | NEMKO USA INC. |
Address Of Test Lab | 802 NORTH KEALY AVE,LEWISVILLE, TX-75057,USA. |
Hyper Link To Test Report | WWW.NEMKO.COM |