220 TB Unified Network Storage Solution with 14-Core Xeon Processor, 256GB DDR4 ECC RAM, Hardware Raid controller with 2GB Cache Protection, 36 Hot Swap Drive Bays for future Expansion, Dual 1GbE and Dual 10 GbE, Redundant Power and Cooling, Linux Based OS with Unlimited User Licenses, Web based GUI for configuration management, Hardware Monitoring and out of band management, Supports SMB, NFS, FTP and iSCSI protocol, and also support integration with ADS/NIS.
Other Specifications Download Specification | |
---|---|
Processor Configuration | E5-2660 v4, 14 core, 2.00GHz with 35 MB cache memory, 105 watt |
Form Factor | Rack |
Processor Make | Intel |
Max. Number Of Sockets Available On Chipset | 2 |
Max. Number Of Sockets Populated With Processor | 2 |
No. Of Processor | 2 |
Number Of Core Per Processor | 14 |
Chipset Compatible With CPU | Intel C612 chipset |
Motherboard (OEMcompatible With CPU) | Yes |
PCI Slots (Express Gen 3.0 Min.) | 5 |
Max Nos Of PCI Lanes | 66 |
Memory ( DDR4 RAM Min.) | 256 GB |
DDR4 RAM Upgradable Upto (Minimum) | Upto 1024GB DDR4 ECC GB |
DIMM Slots (Minumum) | 16 No. |
Hard Disk Drive Capacity | 22 x 10000GB SAS, 2 x 1 TB SSD GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 7200 RPM |
RAID Controller Caches | 2GB MB |
RAID Controller | 12 Gbps SAS Raid Controller |
RAID Controller Ports | 8 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
Bays (min. 2 Internal Or More Hot Plug) | 36 Hot Swap Drive bays either internal or thru JBOD with dedicated 4 No. of NVMe Drive Bays. If JBOD is offered, it is to be connected with SAS 12 Gbps Interface |
USB Ports (version 2.0/3.0) | 4 USB Ports or More |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
DVD ROM (or Better) | 8x or better |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Not-Available |
FC HBA Dual Port Card Speed | NA |
Power Management | Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected |
Redundant Power Supply | Yes |
Redundant Fan | Yes |
Server Scalability To Be Achived Within The Box & Without Adding Nodes | Yes |
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | TR-AERF/MAL/2794F/2016, Dt. 05.08.2016 |
Name & Address Of Lab | NABL/ILAC Approved Laboratory |
BIS Registration No. Under CRS Of Deity | R-91000310 |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | SPEC Int_rate_base 2006 990 & Specfp_rate_2006 770 For Prcessor As Applicable |
Declare Max. Power Consumption Of The System | Redundant and Hot Swappable Power Supplies and Cooling Fans |
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | Benchmark - SPEC CPU 2006, Diagnostic - QuickTech Premium, The OS will be Linux based and will installed on a separate flash/SSD module. The OS will not have any restriction on capacity or number of users. Will have web based GUI for configuration management, Support out of band management for system, Support integration with ADS/NIS, Hardware monitoring and remote management using IPMI, System is Capable of sending email alerts in case of failure of disks, fans and power supplies |
Server Main Supply | 230V, ±10%,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |