1000 lpd fpc nonpr nonhe type1 (redren)(1000 fpc npr nhe type1)

` 161,900.00

  • MRP: `184400.00

1000 LPD Flat Plat Collector Based ISI approved, Non Pressurized And Non Heat Exchanger Solar Water Heater. Insulated Tank - Jindal / Essar - ISI Approved GI Material With Anti Corrosive, Food Grade, Heat Resistant Inner Coating To Protect From Corrosion, Made Through Automated TIG/MIG Welding Machine. Outer Cover - Jindal / Essar - ISI Approved GI Material With Seven Tank Processed And Pure Polyester Powder Coated. Insulation - 50 Mm, High Density, Machine Injected PUF Insulation. Structure - GI Channel With Seven Tank Processed And Pure Polyester Powder Coated. Heating Collector - ISI approved Flat Plat Collector having Copper Tubes..

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 5
  • BIS Approved - Yes
  • If Yes , Mention CM/L No. otherwise put NA - 7902479
  • Model Number of Solar Water Heater System - 1000 FPC NPR NHE TYPE1
  • Region - Type 1 Cold (Areas where ambient temp. reaches 5 degree C or below)
  • Electrical Heater ( Back up ) Capacity - 9 kw
Other Specifications Download Specification
Confirmity To Standards For Solar Water Heating System -Code For Acceptance IS : 12976:1990 with latest amndmt.
BIS Approved Yes
If Yes , Mention CM/L No. Otherwise Put NA 7902479
Model Number Of Solar Water Heater System 1000 FPC NPR NHE TYPE1
Solar Water Heating System Compaitabilty With Heat Exchange Solar Water Heating System without Heat Exchanger
Region Type 1 Cold (Areas where ambient temp. reaches 5 degree C or below)
Rated Capacity In Litres Per Day 1000 LPD
Aperture Area Of Collector , Sq. Meteres 20 Sq Meter
Electrical Heater ( Back Up ) Capacity 9 kw
Capacity Of Make Up Tank( SWHS With Heat Exchanger Only ) NA Ltrs
Solar Flat Plate Shall Be BIS Marked And As Per IS :12933/2003 With Amndmt 1 To 3 Yes
Type Of Cover Plate Conforming To IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum
Solar Transmittance For Cover Plate At Normal Incidence 82 %
Material For Collector Box Aluminium
Numbers Of Collectors 8
Minimum Channel Section Thickness For Sides ( For Al Based) MUST BE >=1.4 Mm Otherwise Put 0 For CRCA Material 1.4 mm
Minimum Thickness Of Sheet For Bottom ( For Al Based), MUST BE >=0.45 Mm Otherwise Put 0 For CRCA Material 0.46 mm
Minimum Thickness Of Sheet Used As Support For Glass Retaining ( For Al Based), MUST BE >=1.2 Mm Otherwise Put 0 For CRCA Material 1.2 mm
Thickness Of Sheet For Entire Body ( For Al Based), MUST BE >=1.0 Mm Otherwise Put 0 For CRCA Material 1 mm
CRCA Material Thickness, Minimum MUST BE >=0.91 Mm Otherwise Put 0 For Al Material 0 mm
Riser And Header Assembly Desigmed For Working Pressure 24.5 K Pa Shall Be Tested For Leakage At A Minimum Hydraulic Pressure Of 490 K Pa Yes
Number Of Absorber Sheets Per Collector 1
Numbers Of Header Tubes 2
Numbers Of Riser Tubes 9
Diameter Of Header Tube 25.4 mm
Diameter Of Riser Tube 12.7 mm
Thickness Of Header Tube 0.71 mm
Thickness Of Riser Tube 0.56 mm
Material Of Riser /Header For Absorber Copper Only
Distanace Between Risers From Center To Center 120 mm
Material Of Sheet For Absorber Copper
Collector Box Insulation Back and sides
Thermal Resistance Of Insulation In Square Degree For Back Face(must Be Greater Than >=0.96) 1.20 W/K m
Thermal Resistance Of Insulation In Square Degree For Side Face(must Be Greater Than >=0.47) 0.60 W/K m
Gasket And Grommets Shall Confirm To IS 12933/2003 With Latest Amndmt. Yes
Material For Hot Water Storage Tank Cold Rolled Steel (other material as per MNRE Notification year2011)
Name The Material If Choose Others NA
Non Pressure Type Hot Water Storage Tank Yes
Position Of Hot Water Tank Horizontal
Thickness Of Sheet Of Hot Water Tank 2.5 mm
Hot Water Tank Insulation Density ( High Density PUF Insulation For 32 Kg/ Meter Cube Or Higher Density 42 mm
Hot Water Welding MIG
Coating Material For Hot Water Tank Polyster Epoxy Plus Balck Epoxy based Paint
Thickness Of Coating 80 micron
Tank Stand Material Mild Steel
Size Of Tank Stand (L X W X H ) Must Be Greater Than 38 X38 X 4 38 x 38 x 4 mm3
Type Of Heat Exchanger cage Type
Material For Heat Exchanger Copper
Thickness Of Tube Of Heat Exchanger , Minimum 22 SWG 22
Heat Transfer Rate For Heat Exchanger , Must Be Greater Than 0.24 Sq Meter Per 100 LPD Capacity 0.24
Numbetrs Of Electrical Heaters ( Back Up Type ) Provided 2
Collector Stand Material Mild Steel
Size Of Collector Tank Stand (L X W X H ) Must Be Greater Than 38 X38 X 4 38 x 38 x 4 mm3
System Interconnecting Pipes Material other material
If Other Mention The Material For Interconnecting Pipes CPVC
Size Of Interconnecting Pipes 25.4 mm
Tank Test Pressure 5 bar
System Working Pressure 1 Bar
Inlet And Outlet Valve Yes
Temp Gauge( For Hot Water ) Yes
Gun Metal Strainer ( For Cold Water ) Yes
Water Meter Yes
Gasket For Flanges Synthetic gasket used between Flanges
Electrical Back Up Control Panel Yes
Make Of Control Panel Others
If Others , Mention The Make Of Control Panel Other Brand
Weight Of Solar Water Heater System 550 kg
Availability Of Schematic Drawing Yes
Instruction Manual For Installation , Repair And Maintanance Yes
Warranty 1 Years
Availability Of Test Report As Per IS : 6893-6 (1985) Used For Purcahse Specification For Machine Tools , Part 6 Bench /Pillar Type Drill Machine With Latest Amndmt.from Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To Specification Yes
Test Report No. HWS-FPC/02/2015 SPRERI/2016/750
Test Report Date 02/01/2016
Name Of The Lab Sardar Patel Renewable Energy Research Institute
Address Of The Lab Post Bos No. 2, Nr. BVM Engineering College, Vallabh Vidhyanagar, Anand - 388120