Expand Your Measurement Range with Increased Flexibility. You can measure around awkward sized conductors with the Fluke 376 True RMS Clamp Meter with iFlex, expanding your measurement range to 2500 A AC. With True RMS voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both AC and DC modes.The Fluke 376 is the direct replacement for the Fluke 337 Clamp Meter.iFlex Flexible Current Probe expands the measurement range to 2500 A AC-CAT IV 600 V, CAT III 1000 V-True RMS AC voltage and current for accurate measurements on non-linear signals-Min, max, average and Inrush recording to capture variations automatically-Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings-Proprietary Inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it-Ergonomic design fits in your hand...
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 34MM |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | -10 °C – +50 °C Degree C Degree C |
Operating Humidity (RH) | ≤ 90 % RH % % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
Standard Accessories Supplied With The Equipment | True-rms AC/DC Clamp Included accessories: 18-inch iFlex™ flexible current probe Coated instruction card Safety information sheet Soft carrying case TL75 test leads Two AA Alkaline batteries |
Dimensions (H X W X L) | 246 mm x 83 m x 43 mm mm x mm x mm x mm x |
Weight | 388 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 3945646 |
Test Report Date | 10 OCT 2017 |
Name Of The Lab | FLUKE |
Warranty | 3 Year |