10 Tera Ohm 10 kV is professional insulation tester, which allows measuring and testing high voltage equipment. DC Test voltage 500 V - 10 kV in step of 25 V The short circuit current is 5 mA Auto - calibation of measuring system Operates from mains or rechargeable supply Automatic discharge of capacitive loads Digital and bar graph results with date and time User friendly PC software with RS232 or USB isolated communication port High quality accessories High noise immunity Highest protection degree CAT IV 600 V.
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | -10 to 50 °C Degree C |
Operating Humidity (RH) | 90 % RH (0 D ÷ 40 D), non-condensing % |
Power Requirements | Battery Operated |
Type Of Battery | 1.2 VDC NiMH D size) |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Mains cable 10 kV shielded test lead with tip, 2 10 kV shielded test lead black, 2 m 10 kV shielded test lead red, 2 m 10 kV crocodile clip, 2 pcs (black, red) Guard lead, green, 2 m Crocodile clip, green 6 x 1.2 V NiMH rechargeable batteries, type D Instruction manual Handbook on CD Calibration certificate |
Dimensions (H X W X L) | 340 x 260 x 160 mm mm x mm x |
Weight | 5500 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | MI3200 |
Test Report Date | 10-07-14 |
Name Of The Lab | Metrel DD Slovenia Europe |
Warranty | 1 |