MI 3103 Insulation Teste 2 GigaOhm 1kV (Metrel)(MI 3103)

` 27,500.00

  • MRP: `32352.00

Insulation resistance measurement,-Continuity measurement using test current of 200 mA in accordance with EN 61557-4 standard,-Continuity measurement continuous measurement using test current of up to 7 mA,-AC / DC voltage measurement. Insulation resistance test voltages 250 V DC, 500 V DC, 1000 V DC,-Automatic discharge of tested item after measurement completion,-Automatic test voltage polarity exchange in Continuity 200 mA function,-Rcon 7 mA function for inductive test items..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - No
Other Specifications Download Specification
Type Portable
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function No
Data Logging NA
Software Not Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 2 milliamper
Operating Temperature Range 0 to 40 °C Degree C
Operating Humidity (RH) 95 % RH (0 D ÷ 40 D), non-condensing %
Power Requirements Battery Operated
Type Of Battery alkaline battery IEC LR14)
PC Interface Available
Standard Accessories Supplied With The Equipment Carrying strap Test lead with test probe, 2 m, (black) Test lead with test probe, 2 m, (red) Crocodile clip (black) Instruction manual Calibration certificate
Dimensions (H X W X L) 280 x 70 x 80 mm mm x mm x
Weight 410 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. MI3103
Test Report Date 10-07-14
Name Of The Lab Metrel DD Slovenia Europe
Warranty 1