Insulation resistance measurement,-Continuity measurement using test current of 200 mA in accordance with EN 61557-4 standard,-Continuity measurement continuous measurement using test current of up to 7 mA,-AC / DC voltage measurement. Insulation resistance test voltages 250 V DC, 500 V DC, 1000 V DC,-Automatic discharge of tested item after measurement completion,-Automatic test voltage polarity exchange in Continuity 200 mA function,-Rcon 7 mA function for inductive test items..
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm |
Test Voltage | 50, 100, 250, 500 and 1000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | No |
Data Logging | NA |
Software | Not Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | 0 to 40 °C Degree C |
Operating Humidity (RH) | 95 % RH (0 D ÷ 40 D), non-condensing % |
Power Requirements | Battery Operated |
Type Of Battery | alkaline battery IEC LR14) |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Carrying strap Test lead with test probe, 2 m, (black) Test lead with test probe, 2 m, (red) Crocodile clip (black) Instruction manual Calibration certificate |
Dimensions (H X W X L) | 280 x 70 x 80 mm mm x mm x |
Weight | 410 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | MI3103 |
Test Report Date | 10-07-14 |
Name Of The Lab | Metrel DD Slovenia Europe |
Warranty | 1 |