MI 2077 Insulation Teste 5 kv 5 tera ohm (Metrel)(MI 2077)

` 149,000.00

  • MRP: `175294.00

MI 2077 Advanced, digital HV measuring instrument with maximum test voltage up to 5000 V DC and resistance measuring range up to 5 T Ohm.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 200 K Ohm to 1 T Ohm
  • Test Voltage - 250, 500, 1000, 2500 and 5000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - No
Other Specifications Download Specification
Type Portable
Measurement Range 200 K Ohm to 1 T Ohm
Test Voltage 250, 500, 1000, 2500 and 5000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function No
Data Logging more than 99 locations
Software Not Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 2 milliamper
Operating Temperature Range -10 to 50 °C Degree C
Operating Humidity (RH) 95 % RH (0 D ÷ 40 D), non-condensing %
Power Requirements Battery Operated
Type Of Battery NiCd or NiMH IEC LR14
PC Interface Available
Standard Accessories Supplied With The Equipment Soft carrying bag Mains cable Test lead, black, 2 m Test lead, red, 2 m Guard lead, green, with crocodile clip, 2 m Test probe, black Test probe, red Crocodile clip, black, 2 pcs Handbook on CD Instruction manual Calibration certificate
Dimensions (H X W X L) 265 x 110 x 185 mm mm x mm x
Weight 2300 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. MI2077
Test Report Date 10-07-14
Name Of The Lab Metrel DD Slovenia Europe
Warranty 1