Very large LCD display with bar graph and back light High measuring range of up to 30 G with test voltage from 50 V to 1000 V Fast and reliable continuity tests with automatic polarity reversal Voltage and frequency measurements Pre programmed limits PASS/FAIL evaluation of measurement result Bright GREEN/RED indicators provides visual evaluation of results Suited for testing on CAT IV installations Magnetic holder allowes hands-free operation Built-in battery charger Two level memory structure for saving of test results and parameters Basic downloading with Euro Link PRO PC SW package Compatible with Euro Link PRO Plus PC SW package USB and RS232 ports Robust and ergonomic design.
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm |
Test Voltage | 50, 100, 250, 500 and 1000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | 0 °C ÷ 40 °C Degree C |
Operating Humidity (RH) | 95 % RH (0 DC ÷ 40 DC), non-condensing % |
Power Requirements | Battery Operated |
Type Of Battery | 1.5 V battery or accu, size AA) |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Soft hand strap Universal test cable 3 x 1,5 m Test tips, 2 pcs (black, red) Alligator clips, 2 pcs (black, red) Power supply adapter + 6 NiMH AA rechargeable batteries Instruction manual on CD Short instruction manual Product verification data Handbook “Guide for testing and verification of low voltage installations” on CD |
Dimensions (H X W X L) | 14 cm x 8 cm x 23 cm mm x mm x |
Weight | 800 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | MI3121 |
Test Report Date | 10-07-2014 |
Name Of The Lab | Metrel DD |
Warranty | 1 |