MI 3210 Tera Ohm XA 10kV is a portable, battery or mains powered test instrument with excellent IP protection IP65, intended for diagnosing of Insulation Resistance by using high DC test voltages of up to 10 kV. Because of its robustness CAT IV protection and high immunity to radiated RF fields it is best suited for industrial environment.
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | -10 to 50 °C Degree C |
Operating Humidity (RH) | 90 % RH (0 D ÷ 40 D), non-condensing % |
Power Requirements | Battery Operated |
Type Of Battery | 3.4 Ah Lead – Acid) |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | 10 kV shielded test lead with probe, 2 m 10 kV shielded test lead, 2 m, 2 pcs (black, red) 10 kV crocodile clip, 2 pcs (black, red) Guard test lead, green, 2 m Crocodile clip, green Mains cable PC SW HVLink PRO with USB and RS 232 cable Handbook "Guide to modern insulation testing" on CD Instruction manual on CD Calibration certificate |
Dimensions (H X W X L) | 360 x 160 x 330 mm mm x mm x |
Weight | 6500 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | MI3210 |
Test Report Date | 10-07-14 |
Name Of The Lab | Metrel DD Slovenia Europe |
Warranty | 1 |