× All the transactions performed on 2.0 is available here. To access Market click "Home".

apc 1100va ups staples (apc 1100va)(bx1100c-in staples)

` 10,999.00

  • MRP: `13700.00

Output power capacity 660Watts / 1.1 kVAMax Configurable Power Watts 660Watts / 1.1 kVANominal Output Voltage 230VEfficiency at Full Load 72.0 Output Frequency sync to mains 50 HzTopology Line InteractiveWaveform type Stepped approximation to a sinewaveTransfer Time 10ms typical 12ms maximumInputNominal Input Voltage 230VInput frequency 45 - 65 Hz auto sensingInput Connections India 3-pin 6ACord Length 1.52metersInput voltage range for main operations 145 - 290VNumber of Power Cords 1Efficiency at Full Load 72.0 Batteries RuntimeBattery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte leakproofTypical recharge time 6hoursRuntimeView Runtime Manual TableCommunications ManagementControl panel LED status display with On Line On Battery Replace Battery and Overload indicatorsAudible Alarm Alarm when on battery distinctive low battery alarm overload continuous tone alarmSurge Protection and FilteringSurge energy rating 255JoulesPh.

  • Availability: 500 In Stock
  • Min. Qty. Per Consignee: 4
  • Technology - MOSFET-PWM with inbuilt isolation transformer
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 800 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1.1 KVA
Technology MOSFET-PWM with inbuilt isolation transformer
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 800 VAH
Voltage Regulation From No Load To Full Load .8 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 35% %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. 83000450
Type Test Certificate Date 09/08/17
Name Of Lab BIS
Address Of Lab DELHI
Supply & Commissioning YES
Warranty 1 Years

Price Dekho Price Dekho Price List in india