TRMS accurate measurements on sinusoidal and non-sinusoidal signals. Jaw size 28 mm. Shielded Jaw shielded jaw allows the clamp meter to be used in the noisiest environments. Accurate readings of AC current with an accuracy of 0.8 and a base resolution of 0.01 mA and voltage with an accuracy of 0.5 and a base resolution of 0.01 V. Power measures various power parameters active, reactive, apparent power, THD, PF, phase displacement. Intelligent loss analysis complex algorithms detect loss and allow determining possible reasons for current loss. Harmonics measures current or voltage harmonic components and a percentage value of a harmonic up to the 19th. THD and PF dual display allows readings to be displayed along with Total Harmonic Distortion THD or Power Factor PF. Peak value the peak value of the waveform or crest factor can be displayed. MAX/MIN/HOLD mode displays maximum, minimum or average measured value..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 28 mm |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | 0 °C ÷ 40 °C Degree C |
Operating Humidity (RH) | 90 % RH (0 D ÷ 40 D), non-condensing % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
Standard Accessories Supplied With The Equipment | Test lead with probe, 2 pcs • 1.5 V battery, type AA, 2 pcs • Pouch • Instruction manual • Warranty |
Dimensions (H X W X L) | 190 x 60 x 43 mm x mm x |
Weight | 255 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | MD9272 |
Test Report Date | 10-07-2014 |
Name Of The Lab | Metrel |
Warranty | 1 Year |