GENERALDetection modesAbsorbanceRead methodsEndpoint, kinetic, spectral scanning, well area scanningMicroplate types6- to 384-well platesOther labware supported Take 3 Micro-Volume PlatesTemperature controlnot availableShakingnot availableSoftwareGen5 Data Analysis SoftwareGen5 Secure for 21 CFR Part 11 compliance optionAutomationBioStack and 3rd party automation compatible R configurationABSORBANCELight sourceXenon flashDetectorphotodiodeWavelength selectionmonochromatorWavelength range200 to 999 nm, in 1 nm incrementsMonochromator bandwidth5 nmDynamic range0 - 4.0 ODResolution0.0001 ODPathlength correctionyesMonochromator wavelength accuracy 2 nmMonochromator wavelength repeatability 0.2 nmOD accuracy0 to 2 OD 1 0.010 OD2 to 2.5 OD 3 0.010 ODOD linearity0 to 2 OD 0.010 OD2 to 2.5 OD 3 0.010 ODOD repeatability0 to 2 OD 1 0.005 OD2 to 2.5 OD 3 0.005 ODReading speed kinetic96 wells 15 seconds384 wells.
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | < 2 |
Type Of Detector | PMT (Photomultiplier Tube) |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | yes |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | 25 Degree C |
Operating Humidity (RH) | 90 % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | EN61236 |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | ce |
Test Report No. | MD19.2126 |
Test Report Date | Jun 02, 2015 |
Name Of The Lab | Biotek Winooski, VT 05404 USA |
Warranty | 1 Year |