Power Quality Analyzer (FLUKE)(435 II Kit with i5sPQ3)

` 723,500.00

  • MRP: `932000.00

Power Quality Analyzer with precision Current clamps.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Display type - LCD Backlit
  • Display Mode - Transient Display
  • Number of Current Channels - 4 Nos Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 0.01 Volts Volts
Other Specifications Download Specification
Type Of Power Analyzer Three phase
Display Type LCD Backlit
Display Mode Transient Display
Number Of Current Channels 4 Nos Nos.
Number Of Voltage Channels 5 Nos Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range 1 to 1000 Volts Volts
Measurable Voltage Accuracy 0.1 %
Measurable Voltage Resolution 0.01 Volts Volts
Facility To Measure RMS Current Available
Measurable Current Range 0.5 to 6000 Amperes Ampere
Measurable Current Accuracy 0.5 %
Measurable Current Resolution 0.1 Ampere Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured 6,000,000 KW KW
Power Accuracy 1 %
Power Resolution 0.1 Watt Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 50 to 3000 Hz Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion 0.1 %
Resolution In Measurement Of Total Harmonics Distortion 0.1 %
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available DC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor 0.1 %
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor 0.1 %
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor 0.1 %
Facility To Measure Voltage And Current Unbalance Available
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range 1 to 10
Measurable Crest Factor Accuracy ± 5 %
Measurable Crest Factor Resolution 0.01
Screen Memory 100
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory 8000 MB MB
Type Of Battery Used Li-ion
Battery Backup 7 hours Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 2000 Grams Grams
Dimensions(LXWXH) 26.5 x 19 x 7 cmXcmXcm cmXcmXcm
Provision For External SD Card Yes
Operating Temperature Range 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery degree celsius degree celsius
Operating Humidity +10 °C ~ +30 °C: 95% RH non-condensing ,+30 °C ~ +40 °C: 75% RH non-condensing ,+40 °C ~ +50 °C: 45% RH non-condensing % %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Main Unit, 5 Voltage Leads with crocodile clips, 4 Current Clamps, 3 Current Clamps, Mains Adapter,
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating CAT III 1000 V, CAT IV 600 V
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. 2204521
TTC Report Date 10/09/2017
Name Of Lab FLUKE
Address Of Lab USA
Interface USB

Price Dekho Price Dekho Price List in india