50MHz, 2 Channle, 7 Inch TFT Display Digital Storage Oscilloscope.
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 1mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, GND |
Time Base Range | 5nS/Div-50S/Div |
Trigger Types | Edge, Pulse, Alternate, Video |
Measurements | Peak, AMplitude, Max, Min, Top, Bottom, Average, RMS, root mean square, ovrshoot, preshoot, frequency, rise time descent time, positive/negative pulse, duty cycle , delay |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal |
Display Type | Colour |
Display Size | 7 Inch TFT CM |
I/O Interface | USB OTG |
Standard Accessories To Be Supplied | Probe X 2Nos, Power Cord, USB Cable, PC software |
Operating Temperature Range | 0-40 degree Degree C |
Operating Humidity (RH) | 90% % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | EN61010-1, EN61326-1, UL61010-1, CAT-I 300V, CE, ROHS, ETL(IntertakeUS) standard Qualified |
Test Report Date | Above certifcates can be provided on request |
Name Of The Lab | Above certifcates can be provided on request |
Warranty | 1 Year |
Real Time Bandwidth | 50 MHz |
Record Length Per Analog Channel Simultaneously | 25Kpts Mega Point |
Sample Rate Per Analog Channel Simultaneously | 500MS/s GS/sec |
Waveform Update Rate | >2000Wfms/S Waveforms/ |
Time Base Accuracy | 0.05 PPM |