MD 9250 True RMS CURRENT CLAMP Meter (Metrel)(MD 9250 CURRENT CLAMP)

` 21,600.00

  • MRP: `25758.00

The MD 9250 is the first Clamp Meter that meets over voltage category CAT IV 1000 V. MD 9250 is a high quality clamp meter specially designed for single-hand operation, built-in measuring functions TRMS AC/DC current, voltage, capacitance, temperature and full range resistance makes this instrument an ideal tool for the most demanding applications in the industrial sector. The large jaws capacity of max. 55 mm in diameter allows AC/DC current measurements up to 2000 A. High resolution and accuracy, 2-line LCD display fast data acquisition and transfer via optical interface, non-contact voltage detection, and auto-check function are highlights of the instrument.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - Backlit
  • Measurement Type - True RMS
  • AC Current Measurement Range - 0 to 999.9 Ampere
  • AC Voltage Measurement Range - 0 to 1000 Volt
  • Inrush Current (Integration Time) - 100 millisecon
Other Specifications Download Specification
Type Hand Held
Display Backlit
Measurement Type True RMS
AC Current Measurement Range 0 to 999.9 Ampere
AC Current Measurement Accuracy + or - 2 %
AC Voltage Measurement Range 0 to 1000 Volt
AC Voltage Measurement Accuracy Upto 600 Volts + or - 1 %
AC Voltage Measurement Accuracy Beyond 600 Volts + or - 1.5 %
Inrush Current (Integration Time) 100 millisecon
DC Current Measurement Range 0 to 999.9 Ampere
DC Current Measurement Accuracy + or - 2 %
DC Voltage Measurement Range 1000 Volt
DC Voltage Measurement Accuracy + or - 1 %
Resistance Measurement Range 0 to 4000 Ohm
Resistance Measurement Accuracy + or - 1.5 %
Continuity < or = 30 Ohm
Frequency Measurement Range 10 to 400
Frequency Measurement Accuracy + or - 0.5
Jaw Size (Dia In Closed State) 55 mm
Satety Rating Category III 600 V of IEC 61010 -2-D31
Operating Temperature Range -50 °C ÷ 300 °C Degree C
Operating Humidity (RH) 90 % RH (0 D ÷ 40 D), non-condensing %
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) CE
Standard Accessories Supplied With The Equipment Test lead with probe, 2 pcs Thermocouple probe, type K Pouch 1.5 V battery, type AAA, 2 pcs Instruction manual Warranty
Dimensions (H X W X L) 97 x 43 x 264 mm mm x mm x
Weight 608 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. MD9250
Test Report Date 10-07-2014
Name Of The Lab Metrel
Warranty 1 Year

Price Dekho Price Dekho Price List in india