three phase power quality analyzer flukefluke-435-ii (fluke)(three phase power quality analyzer flukefluke-435-ii)

` 698,380.00

  • MRP: `775983.00

Three Phase Power Quality and Energy Analyzer, Advanced power quality functions, unprecedented energy analysis capabilities,Highest safety rating in the industry 600 V CAT IV/1000 V CAT III rated for use at the service entrance,Power Wave data capture,Power inverter efficiency,Energy monetization,Energy assessment,Frontline troubleshooting,Predictive maintenance,Long-term analysis,Load studies,Measure all three phases and neutral With included four flexible current probes with enhanced thin flex design to fit into the tightest places.Automatic Trending Every measurement is always automatically recorded, without any set-up.Logger function Configure for any test condition with memory for up to 600 parameters at user defined intervals.View graphs and generate reports With included analysis software,Battery life Seven hours,Wireless data download, Warranty-Three Years, Energy Loss Calculator..

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Display type - LCD Backlit
  • Display Mode - 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
  • Number of Current Channels - 4 Nos.
  • Facility to Measure RMS Voltage - Available
  • Measurable voltage resolution - 0.01 Volts
Other Specifications Download Specification
Type Of Power Analyzer Three phase
Display Type LCD Backlit
Display Mode 127 mm x 88 mm (153 mm/6.0 in diagonal) LCD
Number Of Current Channels 4 Nos.
Number Of Voltage Channels 5 Nos.
Facility To Measure RMS Voltage Available
Measurable Voltage Range 1 V to 1000 V Volts Volts
Measurable Voltage Accuracy ± 0.1 %
Measurable Voltage Resolution 0.01 Volts
Facility To Measure RMS Current Available
Measurable Current Range 0.5 A to 6000 A Ampere
Measurable Current Accuracy ± 0.5 % ± 5 counts
Measurable Current Resolution 0.5 A to 600 A -- 0.1 A & 5A to 6000A --- 1A Ampere
Facility To Measure Active, Reactive And Apparent Power Available
Maximum Power That Can Be Measured 6000000 KW
Power Accuracy ± 1 % ± 10 counts
Power Resolution 0.1 W to 1MW Watt
Facility To Measure Active, Reactive And Apparent Energy Available
Facility To Measure Sag(dips) And Swell(surge) Available
Facility To Measure Frequency Available
Frequency Range That Can Be Measured 42.500 Hz to 69.000 Hz Hz Hz
Facility To Measure Total Harmonic Distortion Available
Accuracy In Measurement Of Total Harmonics Distortion ± 2.5 %
Resolution In Measurement Of Total Harmonics Distortion 0.1%
Facility To Measure Inter Harmonics Available
Order(n) To Which Facility To Measure Harmonics Available 1 to 50 Grouping
Facility To Measure Power Factor Available
Accuracy In Measurement Of Power Factor ± 0.1 %
Facility To Measure Distortion Factor Available
Accuracy In Measurement Of Distortion Factor NA
Facility To Measure Ripple Factor Available
Accuracy In Measurement Of Ripple Factor ± 0.1 %
Facility To Measure Voltage And Current Unbalance Available
Facility To Measure Inrush Current Available
Facility To Measure Flicker Available
Facility To Measure Crest Factor Available
Measurable Crest Factor Range 1.0 > 2.8
Measurable Crest Factor Accuracy ± 5 %
Measurable Crest Factor Resolution 0.01
Screen Memory Available
Data Transfer Software Provided For Analysis On PC Yes
Internal Memory 8000 MB
Type Of Battery Used LITHIUM ION
Battery Backup 8 Hours
Power Supply(volts In AC) 230
Weight Of The Analyser 200 Grams
Dimensions(LXWXH) 265 x 190 x 70 cmXcmXcm
Provision For External SD Card Yes
Operating Temperature Range 0 °C ~ +40 °C; 0 °C ~ +50 °C excluding battery degree celsius
Operating Humidity +10 °C ~ +30 °C: 95 % RH non-condensing, +30 °C ~ +40 ~ +50 °C: 45 % RH non-condensing %
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer Yes
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer AVAILABLE
Compliance To IEC 61000-4-30 Yes
Category Of Safety Rating CAT-III 1000V,CAT-1V 600V
Dry Heat Test As Per IS :9000(Part 3/Section 5) Yes
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) Yes
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) Yes
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. Yes
Type Test Report No. 10100
TTC Report Date 03/09/2017
Name Of Lab FLUKE
Address Of Lab FLUKE USA
Interface USB