hcl esc4000 g3 (hcl)(esc4000 g3)

` 458,000.00

  • MRP: `652500.00

ESC4000 G3.

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Form Factor - Tower
  • Processor Make - Intel
  • Max. Number of sockets available on chipset - 2
  • No. of Processor - 1
  • Motherboard (OEMcompatible with CPU) - Yes
Other Specifications Download Specification
Processor Configuration E5-2620 v4, 8 core, 2.10 GHz with 20 MB smart cache memory, 85 watt
Form Factor Tower
Processor Make Intel
Max. Number Of Sockets Available On Chipset 2
Max. Number Of Sockets Populated With Processor 1CPU POPULATE, 1 FREE,
No. Of Processor 1
Number Of Core Per Processor 8
Chipset Compatible With CPU C236
Motherboard (OEMcompatible With CPU) Yes
PCI Slots (Express Gen 3.0 Min.) 4
Max Nos Of PCI Lanes 32
Memory ( DDR4 RAM Min.) 512 GB
DDR4 RAM Upgradable Upto (Minimum) 8 GB
DIMM Slots (Minumum) 4 No.
Hard Disk Drive Capacity 900 GB
Hard Disk Drive RPM With SAS (hot Plug Or Better ) 1000 RPM
RAID Controller Caches 512 MB
RAID Controller RAID 0
RAID Controller Ports 3
Video Controller (support VGA Or Above Resolution) Yes
Keyboard standard
Mouse Optical scroll
Bays (min. 2 Internal Or More Hot Plug) 4
USB Ports (version 2.0/3.0) 3
Certifications, Compliance & Support By Windows, Red Hat Or Novell. Yes
DVD ROM (or Better) 8x or better
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up Yes
FC HBA Dual Port Card Available
FC HBA Dual Port Card Speed 8
Power Management Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected
Redundant Power Supply Yes
Redundant Fan Yes
Server Scalability To Be Achived Within The Box & Without Adding Nodes Yes
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. Yes
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. Yes
Test Report No. & Date AS PER OEM
Name & Address Of Lab AS PER OEM
BIS Registration No. Under CRS Of Deity AS PER OEM
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. 1
Declare Max. Power Consumption Of The System 1.5 KV
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed Yes
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. YES
Server Main Supply 230V, ±10%,50 Hz
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) Yes
RoHS Compliance Yes
Warranty 1 years

Price Dekho Price Dekho Price List in india