3 1/2 digits LCD, Max. reading 1999. Data-Hold Function. Low battery indication. Plug-in insulation tester adapter 500VDCDCAACVACAOHM.ACCESSORIES Test lead.9V BatteryAA Inside. Users ManualDC Voltage 1000V 0.51dgt AC Voltage 200-750V 1.24dgt AC Current 200A-1000A 2.55dgt Resistance 200-20K 1.02dgtContinuity Buzzer Yes Data Hold Yes Power Supply 9V Battery 6F22 Maximum Display 1999 Display Size 14-47mm Product Net Weight 350g Products Size 230-70-37mm.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | NA |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | 55 Degree C |
Operating Humidity (RH) | 95 % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
Standard Accessories Supplied With The Equipment | yes |
Dimensions (H X W X L) | 15 x 100 x 250 mm x mm x mm x mm x |
Weight | 250 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 35121 |
Test Report Date | 12/05/2016 |
Name Of The Lab | delhi |
Warranty | 1 Year |