× All the transactions performed on 2.0 is available here. To access Market click "Home".

digital storage oscilloscope - DSO (UNI-TREND)(UTD2102CEX)

` 28,500.00

  • MRP: `42500.00

100MHz 2 channels, vertical voltage sensitivity 1mV/div 20V/div, 7 inch colour LCD display, USB storage port with for communication with PC, USB drive system software , waveform storage and reproduction, Automatic measurement of 32 waveform parameters..

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - 20ns to 10s ns
Other Specifications Download Specification
Type Digital
Operating System Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width 20ns to 10s ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 1mV/Div to 5 V/Div
Vertical Resolution NA bits
Coupling DC, AC GND
Time Base Range 2 ns/div-50 s/div
Trigger Types Edge, Pluse, Video,Slope,Alternate
Measurements Add, Subtract, Multiply, Divide, FFT
Frequency Analysis Feature Yes
In-built Frequency Counter No
In-built Function Generator No
Acquisition Modes Sampling, Peak Value Detection & average
Display Type Colour
Display Size 7 Inches 64K Color TFT LCD, 800480 CM
I/O Interface USB /OTG
Standard Accessories To Be Supplied Probe2 (1,10 switchable), Power Cord , USB Cable, PC Software CD
Operating Temperature Range 0 to 45 Degree C
Operating Humidity (RH) 90 %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. PMR /549/2017
Test Report Date 01/07/2017
Name Of The Lab FACTORY CALIBRATION
Warranty 1 Year
Real Time Bandwidth 100 MHz
Record Length Per Analog Channel Simultaneously 25 Kpts Mega Point
Sample Rate Per Analog Channel Simultaneously 1 GS/sec
Waveform Update Rate 2000wfms/s Waveforms/
Time Base Accuracy 1 PPM

Price Dekho Price Dekho Price List in india