100MHz 2 channels, vertical voltage sensitivity 1mV/div 20V/div, 7 inch colour LCD display, USB storage port with for communication with PC, USB drive system software , waveform storage and reproduction, Automatic measurement of 32 waveform parameters..
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | 20ns to 10s ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 1mV/Div to 5 V/Div |
Vertical Resolution | NA bits |
Coupling | DC, AC GND |
Time Base Range | 2 ns/div-50 s/div |
Trigger Types | Edge, Pluse, Video,Slope,Alternate |
Measurements | Add, Subtract, Multiply, Divide, FFT |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | No |
In-built Function Generator | No |
Acquisition Modes | Sampling, Peak Value Detection & average |
Display Type | Colour |
Display Size | 7 Inches 64K Color TFT LCD, 800480 CM |
I/O Interface | USB /OTG |
Standard Accessories To Be Supplied | Probe2 (1,10 switchable), Power Cord , USB Cable, PC Software CD |
Operating Temperature Range | 0 to 45 Degree C |
Operating Humidity (RH) | 90 % |
Power Supply | 230V +- 10 , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | PMR /549/2017 |
Test Report Date | 01/07/2017 |
Name Of The Lab | FACTORY CALIBRATION |
Warranty | 1 Year |
Real Time Bandwidth | 100 MHz |
Record Length Per Analog Channel Simultaneously | 25 Kpts Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1 GS/sec |
Waveform Update Rate | 2000wfms/s Waveforms/ |
Time Base Accuracy | 1 PPM |