× All the transactions performed on 2.0 is available here. To access Market click "Home".

fluke 114 digital multimeter (fluke)(fluke 114)

` 20,999.00

  • MRP: `24999.00

Designed for easy one-hand operation, the Fluke 114 true-rms digital multimeter is the perfect troubleshooting tool for go/no go testing. Its AutoVolt capability automatically switches to measure AC or DC voltage, whichever is present. The LoZ function helps identify so-called ghost voltage and prevent false readings..

  • Availability: 1 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 4.5 Digit
  • Measurement Type - True RMS
  • Count - 6000
  • AC Voltage Measurement Accuracy - 0.5 %
  • AC Current Measurement - 3 Ampere
Other Specifications Download Specification
Type Hand Held
Display 4.5 Digit
Measurement Type True RMS
Count 6000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.5 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.5 %
AC Current Measurement 3 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 3 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range 1 to 100 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -40 to 400 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Not Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory NA
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width NA
Safety Rating Category III 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range -10 °C to + 50 °C
Operating Humidity (RH) NA
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Total Voltage Of Battery NA
Standard Accessories Supplied With The Equipment NA
Dimensions (H X W X L) 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") mm x mm x
Weight 550 g gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. TECPL(CAL)/TECL/GP/34060900WS
Test Report Date 12.12.2017
Name Of The Lab Toshniwal Enterprise Controls Private Limited
Warranty 3 Year

Price Dekho Price Dekho Price List in india