The Fluke 1736 Three-Phase Power Logger built with Fluke Connect mobile app and desktop software compatibility gives you the data you need to make critical power quality and energy decisions in real-time. The best test tool for conducting energy studies and basic power quality logging, the 1736 automatically captures and logs over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings.An optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to reduce measurement errors by digitally verifying and correcting common connection errors makes setup easier than ever and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. You can also quickly and easy.
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Three phase |
Display Type | LCD Backlit |
Display Mode | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel |
Number Of Current Channels | 4 Nos. |
Number Of Voltage Channels | 4 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 1000V Volts |
Measurable Voltage Accuracy | ±(0.2% + 0.01%) |
Measurable Voltage Resolution | 0.1 V Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 0.1 A - 1500 A Ampere |
Measurable Current Accuracy | ±(1% + 0.02%) |
Measurable Current Resolution | 0.1 Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 1500 KW |
Power Accuracy | 1.2% + 0.005% |
Power Resolution | 0.01 Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | 42.5 Hz to 69 Hz Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | ±0.5 |
Resolution In Measurement Of Total Harmonics Distortion | 0.1% |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | 2nd to 50th harmonic |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | ±0.025 |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | ±0.025 |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | ±0.025 |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | 1000V |
Measurable Crest Factor Accuracy | 0.1% |
Measurable Crest Factor Resolution | 0.1% |
Screen Memory | STANDARD |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 4000 MB |
Type Of Battery Used | LI- ION |
Battery Backup | 5 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 115 Grams |
Dimensions(LXWXH) | 19.8 cm x 16.7 cm x 5.5 cm cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | -20 °C to +70 °C (-4 °F to 158 °F) degree celsius |
Operating Humidity | 15% to 85% non-condensing % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | i17xx-flex 1500 12" -4, VOLTAGE PROBES -4, POWER CABLE-01 |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | 369724 |
TTC Report Date | 24 OCT 2017 |
Name Of Lab | FLUKE |
Address Of Lab | USA |
Interface | USB |