Machine controller should have following Features-1. squeeze time 2.Welding current 3. Pressure contact 4. Slope time 5. Welding Time 6. Pause time 7. Holding Time 8. 2 time 2 current feature with double pedal only 9. User friendly panel with touch screenAccessories-IR14 cooling equipment - 1, 64 mm depth pipe type set - 1 , Long electrode holder-1, Bar holders with100 mm bars-1.
Other Specifications Download Specification | |
---|---|
Conformation Of Resistance Welding Equipment | IS:4804(Part-I&II)/1968 |
ISI Marked | No |
If ISI Marked, CM/L No. | NA |
Rating At 50% Duty Cycle As Per IS:4804 Pt.II/1968 | 15 KVA |
Type Of Cooling | water cool |
Availability Of Type Test Report From Govt. Lab Or Any NABL/ILAC Approved Lab To Prove Conformity To The Specification | Yes |
Test Report Number | 1016QFL04 |
Date Of Test Report | 05/09/2016 |
Name And Address Of Laboratory | JASANZ, RAJKOT, GUJARAT |
Type Test Report To Be Furnished To The Buyer On Demand | yes |