× All the transactions performed on 2.0 is available here. To access Market click "Home".

online ups gtx 10 kva three phase to single phase scr based (enertech ups pvt ltd)(gtx - 10- kva scr based)

` 90,000.00

  • MRP: `100000.00

ONLINE UPS some of the ideal features likeCharger Electrical VehicleDouble conversion technology is used in this modelA Low input current distortion level with high efficiencyAdvanced network and mobile connectivityActive/passive harmonic filter at the UPS input.Have an active input power factor correctionHave got a built-in galvanic isolation transformer for reducing the common mode noise.IGBT based design for reduced power consumptionHas Hot standby UPS and load sharing mode for 24x7 operationHave SNMP/MODBUS connectivityRugged DesignWide input voltage rangeSuitable for places with huge variation in grid supplyHigh reliabilityLong LifeIdeal for High DC.

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM with inbuilt isolation transformer
  • Input Power - Three phase 300 V - 450V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 20000 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 10 KVA
Technology IGBT-PWM with inbuilt isolation transformer
Input Power Three phase 300 V - 450V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 120 Minutes
Minimum VAH 20000 VAH
Voltage Regulation From No Load To Full Load 0.7 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 91 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. 201605141
Type Test Certificate Date 06/15/2016
Name Of Lab ENERTECH UPS
Address Of Lab ENERTECH UPS PUNE
Supply & Commissioning 100%
Warranty 2 Years

Price Dekho Price Dekho Price List in india