× All the transactions performed on 2.0 is available here. To access Market click "Home".

amprobe ac50a ac leakage clamp meter (amprobe)(amprobe ac50a ac leakage clamp meter)

` 43,200.00

  • MRP: `48070.00

The Amprobe AC50A Clamp Multimeter with leakage current capability measures low AC current in the microamps. Great for applications requiring measurement of leakage and fault currents..

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - Backlit
  • Measurement Type - True RMS
  • AC Current Measurement Range - 0 to 999.9 Ampere
  • AC Voltage Measurement Range - 0 to 1000 Volt
  • Inrush Current (Integration Time) - 100 millisecon
Other Specifications Download Specification
Type Hand Held
Display Backlit
Measurement Type True RMS
AC Current Measurement Range 0 to 999.9 Ampere
AC Current Measurement Accuracy + or - 2 %
AC Voltage Measurement Range 0 to 1000 Volt
AC Voltage Measurement Accuracy Upto 600 Volts + or - 1 %
AC Voltage Measurement Accuracy Beyond 600 Volts + or - 1.5 %
Inrush Current (Integration Time) 100 millisecon
DC Current Measurement Range 0 to 999.9 Ampere
DC Current Measurement Accuracy + or - 2 %
DC Voltage Measurement Range 1000 Volt
DC Voltage Measurement Accuracy + or - 1 %
Resistance Measurement Range 0 to 4000 Ohm
Resistance Measurement Accuracy + or - 1.5 %
Continuity < or = 30 Ohm
Frequency Measurement Range 10 to 400
Frequency Measurement Accuracy + or - 0.5
Jaw Size (Dia In Closed State) 40 mm
Satety Rating Category III 600 V of IEC 61010 -2-D31
Operating Temperature Range -10° C … 50° C (14° F... 122° F) Degree C
Operating Humidity (RH) < 75 % relative humidity %
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
Standard Accessories Supplied With The Equipment Standard
Dimensions (H X W X L) 176 x 64 x 23 mm x mm x
Weight 125 gms gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. 3945665
Test Report Date 10 Oct 17
Name Of The Lab Amprobe
Warranty 1 Year

Price Dekho Price Dekho Price List in india