Scale Grading 2mmHg Measuring Range 0-300mmHg Measuring Precision - 3mmHg The lowest value of the scale is 0 The Aneroid needle in 0 position must be within in a tolerance of -3mmHg Packed in soft case Soft Cotton Nylon cuff Never inflame to more than 300mmHg Emulsoid Bladder Soft emulsoid Bulb Leather bag easy to carry Latex-free for safety. Laser-engraved dial face for accuracy Certified accurate to - 3mmHg A compact and reliable Blood Pressure Instrument supplied with adult Velcro fabric cuff Precision manometer with clip for fixing to cuff.ISO CE NSIC And ISI Mark..
Other Specifications Download Specification | |
---|---|
Type Of SPHYGMOMANOMETERS(B.P.Apparatus) | Aneroid |
Conformity To Indian Standrad For SPHYGMOMANOMETERS | IS 7652 latest for Aneroid |
ISI MARKED | Yes |
CM/L No And Validity Date | 8677810 31 October 2017 |
Measuring Device | Mechnical |
Type | Portable |
Measurement Method | Oscillometric |
Display For Digital BP Instrument: | NA for others |
Range: Pressure Measurement | 0 to 300 mmHg |
Range:Pulse Measurement For Digital With Accuracy ± 5%. | 40 to 200 per minute |
Accuracy:Pressure Measurement | ± 3 mmHg |
Pressure Detection | Capacitive Pressure sensor |
Inflation | Manual |
Deflation And Rapid Air Release | Manual |
Cuff Range | Large (32-45)cm |
Dimensions Of The Equipment | 13CM X 7.5CM X 18CM L X W X H mmXmm mmXmm |
Dimensions Of The Display Screen | 50MM mmXmm mmXmm |
Operating Temperature | 0 to 55 °c |
Stroage Temperature | (-10) to 55 °c |
Power Source:Chargeable 4 Nos AA Size Batteries.Operated With Battery Charger(for DIGITAL). | Yes |
Type Of Battery(4 Nos AA Size) | Alkaline |
Automatic Power Off If System Is Idle For 3 Minutes. | Yes |
Weight | 500gms kg Kgs |
CE Marking Certificate For B.P. Apparatus Model. | Yes |
For Digital Sphygmomanometer ,Availability Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A). Dry Heat Test (For 16 Hrs At A Temp. Of 55degree C In Accordance With IS: 9000/part-3/section-3/1977)latest. | Yes |
B). Cold Test(For 4 Hrs At A Temp. Of (-10) Degree C In Accordance With IS: 9000/part-2/section-3/1977latest. | Yes |
C).Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 55 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981)latest. Note:- The B.P.Instrument Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, B.P.Instrument Shall Be Functional. " | Yes |
Availability Of Type Test Report Covering Complete Test Parameters As Per IS3390 Latest For Mercurial And IS7652 Latest For Aneriod Type, From Any ILAC/NABL Accredited/Central Gov. LAB.For Digital Type Including Environmental Test From Any ILAC/NABL Accredited/Central Gov. LAB | Yes |
Test Cetificate No. | na |
Test Report Date | na |
Name And Address Of The Lab Where Test Conducted. | na |
Others Certificate Ie ROHS,WHO,GMP Etc. | CE NSIC WHO GMP |
Conformity To OILM-R-16-1 And OILM-R-16-2 For Both Non-invasive Mechanical Sphygmomanometers And Non-invasive Automated Sphygmomanometers Are For Guidance And All The Gazette Of India Related To Legal Metrology Issued Time To Time, Are Applicable To The Specification As Well As To The Product. | Yes |
Warranty Time | 1 Year |