AmpTipTM low-current range calibrated at Jaw-tip for slim-conditionsMAX/MIN/AVG Recording mode Auto rangingVFD-V Hz for fundamental V/Hz of most Variable-Frequency-DrivesDisplay Hold Non-Contact EF-Detection NCVBack-lighted easy-to-read LCD displayFlashlight for easy operation in dim areasFast 80ms Peak-RMS mode to capture in-rush currentsRelative mode with DC-Zero mode 5ms Crest Instantaneous Peak-Hold mode..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | Backlit |
Measurement Type | True RMS |
AC Current Measurement Range | 0 to 999.9 Ampere |
AC Current Measurement Accuracy | + or - 2 % |
AC Voltage Measurement Range | 0 to 1000 Volt |
AC Voltage Measurement Accuracy Upto 600 Volts | + or - 1 % |
AC Voltage Measurement Accuracy Beyond 600 Volts | + or - 1.5 % |
Inrush Current (Integration Time) | 100 millisecon |
DC Current Measurement Range | 0 to 999.9 Ampere |
DC Current Measurement Accuracy | + or - 2 % |
DC Voltage Measurement Range | 1000 Volt |
DC Voltage Measurement Accuracy | + or - 1 % |
Resistance Measurement Range | 0 to 4000 Ohm |
Resistance Measurement Accuracy | + or - 1.5 % |
Continuity | < or = 30 Ohm |
Frequency Measurement Range | 10 to 400 |
Frequency Measurement Accuracy | + or - 0.5 |
Jaw Size (Dia In Closed State) | 51mm Max. |
Satety Rating | Category III 600 V of IEC 61010 -2-D31 |
Operating Temperature Range | -10ºC to 50ºC Degree C |
Operating Humidity (RH) | Maximum 90%R.H. at 10-30°C % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
Standard Accessories Supplied With The Equipment | Test leads set, Users Manual, Soft carrying pouch. |
Dimensions (H X W X L) | 258(L) x 94(W) x 44(H)mm mm x mm x |
Weight | 392 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 54678789 |
Test Report Date | 1/11/17 |
Name Of The Lab | kusam meco |
Warranty | 1 Year |