CyberPower UT1000E provides home and office users a reliable battery backup and safeguard office PCs, network communication equipment, and other electronic devices from surges, spikes, brownouts and other power incidents.The product is generator-compatible, which allows users flexible application scenario planning for power outages. The built-in Automatic Voltage Regulation AVR stabilizes the AC signal allowing the UPS to deliver power at safe voltage levels to all connected equipment without resorting to battery power..
Other Specifications Download Specification | |
---|---|
Rating In KVA/ Min VAH Capacity Of Battery | 1.0/168 KVA/VAH |
Technology | MOSFET-PWM |
Input | Single phase sinewave(160-280v) Volt |
Rated Output | Single phase sinewave 230v AC , 50Hz Volt |
Load Power Factor | 0.6 |
Variation In AVR Output In AC Mode | 9 % |
Variation In Output Voltage In Battery Mode | 10 % |
Variation On Output Frequency In Battery Mode | 0.5 Hz |
Inverter Efficiency | 87 % |
Total Harmonic Distorsion | 2 % |
Switching Over Time | 4 Mili sec |
Overload | 10 % |
Overload Time | 10 Minutes |
Protection Against Short Circuit Of UPS | Yes |
Protection For Outside Input Voltage Range | 280 Volt |
Protection Against Discharge Per 12v Battery | 10.5 Volt |
Degree Of Protection | IP-21 |
Type Of Battery | SMF-VRLA confirming to JISC-8702 Pt 1,2 &3 |
Type Of Enclosure | ABS |
Dry Heat Test At 45 Degree For 16 Hrs As Per IS:9000 Pt-3/sec-5 | Yes |
Damp Heat Test At 45 Degree , RH -95% For 2-cycle As Per IS:9000 Pt-5/sec-1 | Yes |
Cold Test As Per IS:9000 Pt-2/sec-4 | Yes |
Availability Of The Type Test Report From Central Govt./NABL/ILAC Accredited Lab | Yes |
Type Test Certificate No. And Date | BIS, ROHS |
Name Of Lab | BIS, ROHS |
Address Of Lab | BIS, ROHS |