MEGGER-DET14C -Digital Earth test clamps on meter with wide ground loop resistance range, from 0.05 ohm to1500 ohm to satisfy all requirements, Large jaw opening of 39 mm for tests on ground conductors and/or equipotential bus bars, Measurement of True RMS ground leakage current, from 0.5mA to 35A, without needing to disconnect the ground-ideal for system troubleshooting, Wide AC current with Auto ranging feature allows an instrument for multiple applications. High and Low Alarm function, for rapid measurement evaluation, Handy display hold function for capturing readings in hard-to-reach places, having data storage capacity up to 256 records, Cat IV 600V protection for safety, Automatic self-calibration ensures correct measurement everytime, Overload protection-200A for 60s,24 hours battery life continuous operation. 2pole method for resistance measurement-NA For more info please refer datasheet of OEM. Warranty one year on main instrument-accessories. Price inclusive ofGST@18percent.
Other Specifications Download Specification | |
---|---|
Display Type | 3 digit LCD display |
Measurable Earth Resistance Range | Auto ranging |
2-pole Method For Resistance Measurement | YES |
3-pole Method For Resistance Measurement | NO |
4-pole Method For Resistance Measurement | YES |
Number Of The Stakes | NA NOS. |
Material Of The Stakes | NA |
Length Of The Stakes | NA cm |
Diameter Of The Stakes | NA cm |
Number Of The Test Leads | NA Nos. |
Length Of The Test Leads | NA cm |
No. Of Test Leads With Clamps | NA Nos. |
Length Of Test Leads With Clamps | NA cm |
Measuring Range1 For Earth Resistance | 0.05 to 0.99 Ohms |
Measuring Range2 For Earth Resistance | 1.00 to 9.99 Ohms |
Measuring Range3 For Earth Resistance | 10.0 to 99.9 Ohms |
Measuring Range4 For Earth Resistance | 100.0 to 199.9 Ohms |
Measuring Range5 For Earth Resistance | 200 to 400 Ohms |
Measuring Range6 For Earth Resistance | 400 to 600 Ohms |
Measuring Range7 For Earth Resistance | 600 to 1200 Ohms |
Measurable Earth Resistance Resolution For Range1 | 0.01 Ohms |
Measurable Earth Resistance Resolution For Range2 | 0.01 Ohms |
Measurable Earth Resistance Resolution For Range3 | 0.1 Ohms |
Measurable Earth Resistance Resolution For Range4 | 0.1 Ohms |
Measurable Earth Resistance Resolution For Range5 | 1 Ohms |
Measurable Earth Resistance Resolution For Range6 | 1 Ohms |
Measurable Earth Resistance Resolution For Range7 | 10 Ohms |
Measurable Earth Resistance Accuracy For Range1 | 1.5 0.05 ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range2 | 1.5 0.1 ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range3 | 2 0.5 ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range4 | 5 1 ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range5 | 10 10 ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range6 | 10 10 ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range7 | 20 ±% reading ± digits |
Stakeless Test(Clamp On) | yes |
Facility To Measure Earth Voltage | Not Available |
If Yes,Measurable Earth Voltage Range | NA Volts |
If Yes,Measurable Earth Voltage Accuracy | NA % |
Minimum Open Circuit Output Voltage | NA Volts |
Low Battery Indication | Available |
Over Range Indication | Available |
If Yes,Measurable Earth Voltage Resolution | NA Volts |
Internal Memory | 256 records |
Type Of Battery Used In The Power Supply | AA (Alkaline) (4 required) |
Battery Backup Time | 24hrs Hours |
Battery Charger Provided With The Meter. | NA |
Weight Of The Tester | 985 g grams |
Dimensions(LXWXH) | 248 mm (l) x 114 mm (b) x 49 mm cmXcmXcm |
Provision For External SD Card | No |
Interface | NA |
Operating Temperature Range | -20 C to +50 C, degree celsius degree celsius |
Operating Humidity Range | -40 C to +60 C, % |
All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Carrying case, Carrying strap (wrist loop) User guide CD-ROM, Calibration check, Battery AA (Alkaline) (4 required) |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. | Yes |
Type Test Report No. | 6672/10-401 |
TTC Report Date | 1-JUNE-2010 |
Name Of Lab | TRAC |
Address Of Lab | RINGWOOD UK |