Digital Earth clamp Megger DET 14 c.
Other Specifications Download Specification | |
---|---|
Display Type | 3 digit LCD display |
Measurable Earth Resistance Range | Auto ranging |
2-pole Method For Resistance Measurement | YES |
3-pole Method For Resistance Measurement | NO |
4-pole Method For Resistance Measurement | YES |
Number Of The Stakes | 4 NOS NOS. |
Material Of The Stakes | Metal |
Length Of The Stakes | 450mm cm cm |
Diameter Of The Stakes | 10mm cm cm |
Number Of The Test Leads | 4 Nos. Nos. |
Length Of The Test Leads | 10,20,30,40 cm cm |
No. Of Test Leads With Clamps | 4 Nos Nos. |
Length Of Test Leads With Clamps | 10,20,30,40 cm cm |
Measuring Range1 For Earth Resistance | 0.05 to 0.99ohm Ohms Ohms |
Measuring Range2 For Earth Resistance | 1.00ohm to 9.99ohm Ohms Ohms |
Measuring Range3 For Earth Resistance | 10.ohm to 99.9 Ohm Ohms Ohms |
Measuring Range4 For Earth Resistance | 100ohm to 199.9ohm Ohms Ohms |
Measuring Range5 For Earth Resistance | 200ohm to 400 ohm Ohms Ohms |
Measuring Range6 For Earth Resistance | 400ohm to 600 ohm Ohms Ohms |
Measuring Range7 For Earth Resistance | 600ohm to 1200ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range1 | 1200ohm to 1500ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range2 | 1ohm to 1500ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range3 | 1ohm to 1500ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range4 | 1ohm to 1500ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range5 | 1ohm to 1500ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range6 | 1ohm to 1500ohm Ohms Ohms |
Measurable Earth Resistance Resolution For Range7 | 1ohm to 1500ohm Ohms Ohms |
Measurable Earth Resistance Accuracy For Range1 | +=1.5+ digit +- reading +- digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range2 | +=1.5+ digit +- reading +- digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range3 | +=1.4+5 digit +- reading +- digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range4 | +=1.5+4digit +- reading +- digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range5 | +=1.5+ 5digit +- reading +- digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range6 | +=1.5+ 5digit +- reading +- digits ±% reading ± digits |
Measurable Earth Resistance Accuracy For Range7 | +=1.5+ 5digit +- reading +- digits ±% reading ± digits |
Stakeless Test(Clamp On) | yes |
Facility To Measure Earth Voltage | Available |
If Yes,Measurable Earth Voltage Range | 0-200v Volts Volts |
If Yes,Measurable Earth Voltage Accuracy | += 2 % |
Minimum Open Circuit Output Voltage | 36v Volts Volts |
Low Battery Indication | Available |
Over Range Indication | Available |
If Yes,Measurable Earth Voltage Resolution | 0.1v Volts Volts |
Internal Memory | No |
Type Of Battery Used In The Power Supply | 4x1.5v IEC-LR6 ALKALIN |
Battery Backup Time | 24HR Hours Hours |
Battery Charger Provided With The Meter. | Yes |
Weight Of The Tester | 550GRM grams grams |
Dimensions(LXWXH) | 180x100x54cmXcmXcm cmXcmXcm |
Provision For External SD Card | No |
Interface | No |
Operating Temperature Range | 0-55C degree celsius degree celsius |
Operating Humidity Range | 95rhNON CONDTING % |
All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Tester. | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification Including Environmental Test Sequence. 1. Dry Heat Test As Per IS :9000(Part 3/Section 5) 2.Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) 3.Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4). After Completion Of Environmental Conditioning Sequence As Specified And Recovery Of 2 Hours, The Functional Parameters Of Earth Resistance Meter Shall Be Checked. | Yes |
Type Test Report No. | is9223 |
TTC Report Date | 25/06/2015 |
Name Of Lab | ERTL |
Address Of Lab | Ad Andhari Mumbay |